<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1385</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2006</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>16</volume>
<number>54</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بهینه سازی نگاره های MRA مغز با استفاده از ماده کنتر است زا در میدان مغناطیسی 1.5 تسلا</title_fa>
	<title>Optimization of brain MRA with contrast injection in 1.5 T field</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify direction: rtl&quot;&gt;
&lt;span style=&quot;font-weight: bold&quot;&gt;سابقه و هدف: &lt;/span&gt;برای انجام آنژیوگرافی با استفاده از رزونانس مغناطیسی (Magnetic Resonance Angiography) MRA از مغز با توجه به وضعیت خاص شریا‌ن ها و وریدهای آن که دارای سرعت های متفاوت خون است، نه تنها باید در انتخاب پارامترهای تصویربرداری دقت خاصی داشت، بلکه باید موقعیت تشریحی عروق مورد مطالعه را نیز در نظر گرفت؛ به نحوی که به علت سرعت آهسته جریان خون در سیستم وریدی و شریان های کوچک در مغز استفاده از ماده شبه مغناطیس (Paramagnet) پیشنهاد می شود. به همین علت در این مطالعه بهینه سازی پارامترهای تصویربرداری عروق مغزی با استفاده از مواد کنتراست زا در میدان مغناطیسی 1.5 تسلا برای اولین بار در ایران مورد بررسی قرار گرفت.&lt;br&gt;&lt;span style=&quot;font-weight: bold&quot;&gt;مواد و روش ها:&lt;/span&gt; برای بهینه سازی نگاره ها به دنبال به دست آوردن T1 تقریبی خون پس از تزریق بر اساس مقدار mmol/kg 0.1 در ms 1200 و 900 ، 600 ، 300 =T1 مقدار سیگنال نسبی برای زمان اکو ms 7 TE= و زمان تکرار 20 ms=TR به دست آمده و نشان داد که با کاهش T1 مقدار زاویهارنست و شدت نشان نسبی افزایش می یابد. سپس با استفاده از پارامترهای زمان اکو ms 7 TE= ، زمان تکرار 20 ms=TR‌و درجه انحراف 30، 20،10=FA (Flip Angle) تصاویر بدون تزریق و در حال تزریق در سه گروه پنج نفره داوطلب به دست آمد. پس از اندازه گیری سیگنال در نواحی شریان کاروتید، شریان میانی مغز، سیستم وریدی و انحراف ‌معیار در هوا مقدار C/N (Contrast to Noise) محاسبه شد. با توجه به اندازه گیری های انجام شده زاویه انحراف 20 درجه دارای بالاترین مقدار C/N بود.در مرحله نهایی با استفاده از پارامترهای ([TR/TE/FA] 20ms/7ms/20?) و زمان اسکنچهار دقیقه تصاویر بدون تزریق، در حال تزریق و 15 دقیقه پس از تزریق در 20 بیمار داوطلب تهیه و مقدار C/N محاسبه شد.&lt;br&gt;&lt;span style=&quot;font-weight: bold&quot;&gt;یافته ها:&lt;/span&gt; پس از انجام آزمون های آماری مناسب، بالاترین مقدار C/N در تصاویر در حال تزریق دیده شد. برای اطمینان از معنی دار بودن تفاوت میانگین ها با استفاده از آزمون آماری t دانشجو C/N تصاویردو بهدو با یکدیگر مقایسه شدند. برای بررسی بالینی پس از تهیه تصاویر بر روی فیلم تعداد یک وریدو دو شریان که C/N آن اندازه گرفته شد بر اساس پنج درجه کیفی تعریف شده و مورد بررسی قرار گرفتند.&lt;br&gt;&lt;span style=&quot;font-weight: bold&quot;&gt;استنتاج:&lt;/span&gt; تزریق ماده شبه مغناطیس ایجاد کننده تضاد در مشاهده بهترشریان هایریز و وریدها موثر بود. زیرا این عروق دارای جریان خون کمی بوده و با توجه به تعداد پالس RF (Radio Frequency)که دریافت می‌کنند C/N قابل توجهی ندارند، ولی پس از تزریق ماده شبه مغناطیسی و کاهش T1 خون و انتخاب پارا مترهای متناسب با آن مقدار C/N افزایش می یابد.
&lt;/div&gt;</abstract_fa>
	<abstract>
&lt;span style=&quot;font-weight: bold&quot;&gt;Background and purpose:&lt;/span&gt; Selection of suitable parameters for brain MRA requires accurate measures, because the image quality depends on the location of arteries, veins and also the velocity differences of blood, taking into account the low blood flow in small veins and arteries, use of paramagnetic contrast media is recommended. Hence, in present study, we investigated the imaging optimization of brain vessels using contrast media in 1.5 T field.

&lt;br&gt;&lt;span style=&quot;font-weight: bold&quot;&gt;Materials and Methods: &lt;/span&gt;For image optimization blood T1 was estimated after the injection of 0.1mmol/kg of Gd-DTPA and the relative blood signals were measured at T1=300, 600, 900 and 1200ms using TR=20ms and TE=7ms parameters. Ernest angle and relative signal increased as the T1 decreased. MRA was obtained in three groups, each including five volunteer patients using parameters TR=20ms, TE=7ms and flip angle 10, 20 &amp; 30 degrees in two series without and during contrast injection.

Signals of carotid, M.C.A and thorcolar herofili and SD in air were measured and it was shown that in 20 degrees flip angle, C/N was maximum.

At the last stage, three series of MRA, without, during c.i and 15 minutes after c.i where obtained in 20 volunteer patients using parameters TR=20ms, TE=7ms and flip angle 20 degrees and calculated C/N .

&lt;br&gt;&lt;span style=&quot;font-weight: bold&quot;&gt;Results:&lt;/span&gt; After statistical analysis the highest C/N was observed during c.i MRA. Paired
t-student test was performed to compare the differences between the C/N ratios. For clinical purposes one vein and two arterles were graded in 5 definite levels.

&lt;br&gt;&lt;span style=&quot;font-weight: bold&quot;&gt;Conclusion:&lt;/span&gt; Results indicated an important effect of paramagnetic contrast media on better observing of small arteries and vein. The best quality was taken during c.i, but in some arteries contrast media did not improve the quality of MRA
</abstract>
	<keyword_fa>تسلا / مغز، ماده کنتراست زا پارامگنت، میدان مغناطیسی 5 MRA</keyword_fa>
	<keyword>brain MRA, paramagnetic contrast media, 1.5 T field</keyword>
	<start_page>27</start_page>
	<end_page>34</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-1-131&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>B</first_name>
	<middle_name></middle_name>
	<last_name>Rafiee</last_name>
	<suffix></suffix>
	<first_name_fa>بهروز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رفیعی </last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846006239</code>
	<orcid>10031947532846006239</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>N</first_name>
	<middle_name></middle_name>
	<last_name>Riyahi Alam</last_name>
	<suffix></suffix>
	<first_name_fa>نادر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ریاحی عالم </last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846006240</code>
	<orcid>10031947532846006240</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>B</first_name>
	<middle_name></middle_name>
	<last_name>Bolori</last_name>
	<suffix></suffix>
	<first_name_fa>بهرام</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بلوری </last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846006241</code>
	<orcid>10031947532846006241</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M.A</first_name>
	<middle_name></middle_name>
	<last_name>Aqabiyan</last_name>
	<suffix></suffix>
	<first_name_fa>محمدعلی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عقابیان </last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846006242</code>
	<orcid>10031947532846006242</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>H</first_name>
	<middle_name></middle_name>
	<last_name>Hashemi</last_name>
	<suffix></suffix>
	<first_name_fa>حسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هاشمی </last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846006243</code>
	<orcid>10031947532846006243</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>S.A</first_name>
	<middle_name></middle_name>
	<last_name>Rahimi</last_name>
	<suffix></suffix>
	<first_name_fa>سیدعلی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رحیمی </last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846006244</code>
	<orcid>10031947532846006244</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>H</first_name>
	<middle_name></middle_name>
	<last_name>Qenaati</last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قناعتی </last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846006245</code>
	<orcid>10031947532846006245</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
