<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1390</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2012</year>
	<month>2</month>
	<day>1</day>
</pubdate>
<volume>21</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی میزان میدان مغناطیسی بافرکانس بی‌نهایت پایین (ELF) شهر تهران در سال 1391</title_fa>
	<title>Evaluation of extremely low-frequency magnetic field (ELF) at Tehran City in 2012</title>
	<subject_fa>بهداشت محیط زیست</subject_fa>
	<subject>Environmental Health</subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>سابقه و اهداف : خطوط انتقال برق از منابع تولید میدان مغناطیسی با فرکانس بی نهایت پایین محسوب می‌گردد. هدف از این مطالعه بررسی چگالی شار مغناطیسی با فرکانس‌های بی نهایت پایین (ELF ) در اطراف خطوط فشار قوی برق منطقه غرب تهران درسال 1391 بود.
مواد و روشها: در این مطالعه چگالی شار مغناطیسی در اطراف سه خط فشار قوی انتقال برق 63، 230 و 400 کیلوولت اندازه گیری شد. اندازه گیری‌ها  با استفاده از دستگاه سه محوره قرائت مستقیمTES 1394 براساس استاندارد 1994-644  IEEE در فواصل(0،5،10،20) متر از خطوط انجام شد.
یافته ها: نتایج حاصله نشان داد که حداقل، میانگین و حداکثر چگالی شارمغناطیسی در اطراف خطوط به ترتیب 14/0، 25/1± 43/1، 51/11میکروتسلا بود. مقدار چگالی شار مغناطیسی در تمامی قرائت‌ها پایین‌تر از حد استاندارد کمیسیون بین‌المللی حفاظت در برابر پرتوهای غیریونساز بود.
استنتاج : میانگین چگالی شار مغناطیسی در اطراف خطوط حدود 25/1% استانداردICNIRP بود و همچنین این میزان با افزایش فاصله از خطوط و کاهش جریان عبوری از خطوط کاهش یافت.
</abstract_fa>
	<abstract>Introduction: The power transmission lines are the emission source of  extremely low frequency (ELF) electromagnetic fields that are considered to have an adverse impact on human health. Therefore the aim of this study was to evaluate the  amount of magnetic flux with extremely low frequencies (ELF) around high voltage power transmission lines in the western areas of Tehran in 2012.
Material and Method: In this study the magnetic flux density was measured around three lines of high voltage electricity transmission (63, 230 and 400 kV). The employed device for magnetic flux measurement  was Triple  axis TES 1394  tester. The measurements  were taken according to IEEE standard procedures (Std 644-1994) in  four distance ( 0, 5, 10 and 20 m).
Results: The results showed that the amount of the minimum, mean and maximum of magnetic flux density were 0.14,1.43 ±1.25 and 11.51µT respectively. The flux density was lower than the standard international commission on ionizing radiation protection in all cases.
Discussion and Conclusion: The average level of magnetic flux density  was about 1.25% of the exposure limit ICNIRP standard (100 µT) around  the three lines.  Also the magnetic flux density rate decreases with increasing distance from the line and decreasing flow.
</abstract>
	<keyword_fa>میدان مغناطیسی، چگالی شار مغناطیسی، فرکانس بی نهایت کم، پرتوهای غیر یونساز، خطوط فشار قوی انتقال برق</keyword_fa>
	<keyword>Magnetic Field, Magnetic flux density, Extremely Low Frequency (ELF), Non – Ionizing radiation (NIR), High voltage transmission line.</keyword>
	<start_page>146</start_page>
	<end_page>151</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-29-93&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammad Ali </first_name>
	<middle_name></middle_name>
	<last_name>Zazoul</last_name>
	<suffix></suffix>
	<first_name_fa>محمدعلی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ززولی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460018781</code>
	<orcid>100319475328460018781</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Reza </first_name>
	<middle_name></middle_name>
	<last_name>Monazzam</last_name>
	<suffix></suffix>
	<first_name_fa>محمدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>منظم</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460018782</code>
	<orcid>100319475328460018782</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Jamshid</first_name>
	<middle_name></middle_name>
	<last_name>Yazdani Charati</last_name>
	<suffix></suffix>
	<first_name_fa>جمشید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یزدانی چراتی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460018783</code>
	<orcid>100319475328460018783</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Fatemeh</first_name>
	<middle_name></middle_name>
	<last_name>Hosseinzadeh</last_name>
	<suffix></suffix>
	<first_name_fa>فاطمه </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسین زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>fatemehosseinzadeh63@yahoo.com</email>
	<code>100319475328460018784</code>
	<orcid>100319475328460018784</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
