<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>24</volume>
<number>116</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی کولیماتورهای لایه‌ای در تصویربرداری تابش ترمزی حین رادیو دارو درمانی با فسفر-32</title_fa>
	<title>Assessment of Layer Collimator in Bremsstrahlung Imaging during Radionuclide Therapy with Phosphorus-32</title>
	<subject_fa>فیزیک پزشکی</subject_fa>
	<subject>Medical physics</subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>سابقه و هدف: تصویربرداری در پزشکی هسته‌ای بر پایه استفاده از تابش گاما می‌باشد و درمان در پزشکی هسته‌ای با استفاده از رادیوداروهای تابش کننده بتا صورت می‌گیرد. استفاده از اشعه ترمزی برای تصویربرداری و تعیین توزیع رادیو ایزوتوپ‌ها زمینه‌ای جدید در تحقیقات می‌باشد. در تصویربرداری تابش ترمزی یا ترمزی طراحی کولیماتور نباید بر اساس پیک انرژی باشد و تمام طیف انرژی در تحلیل باید در نظر گرفته شود. بزرگ‌ترین مسئله که برای این پرتوها وجود دارد مسئله نفوذ از دیواره کولیماتور است. در این تحقیق یک طراحی جدید کولیماتور برای تصویربرداری تابش ترمزی با نصف وزن معمول کولیماتورها پیشنهاد شده است. بااین‌حال تغییر چندانی در رزولوشن و حساسیت سیستم ایجاد نخواهد شد. همچنین میزان تأثیر فیلتر واینر در تصویربرداری تابش ترمزی مورد ارزیابی قرار گرفت.
مواد و روش ها: با کد شبیه‌ساز GATE کولیماتورهای لایه‌ای به‌صورت فانتوم دیجیتالی طراحی شد و حساسیت و رزولوشن کولیماتورهای لایه‌ای در لایه‌های مختلف مورد ارزیابی قرار گرفت.
یافته ها: با افزایش تعداد لایه‌های کولیماتور حساسیت تا میزان 9درصد افزایش یافت. همچنین به دلیل نفوذ از دیواره رزولوشن تا 11درصد کاهش پیدا کرد. علاوه بر این، هیچ دلیل قانع‌کننده‌ای که نشان دهد فیلتر واینر در تصویربرداری تابش ترمزی موجب بهبود رزولوشن می‌شود، مشاهده نشد.
استنتاج: کولیماتورهای لایه‌ای موجب افزایش حساسیت می‌شود و زمان جمع‌آوری کانت را برای تصویربرداری تابش ترمزی کاهش می‌دهد.
</abstract_fa>
	<abstract>Background and purpose: Imaging which is used in nuclear medicine is done using emit gamma rays whereas therapy in nuclear medicine is performed by applying radionuclide’s which emit beta radiation. Using Bremsstrahlung is a new field which is recently introduced in imaging. In the Bremsstrahlung imaging, collimator design should not be based on energy peak and whole energy spectrum should be considered. The main problem of these radiations is collimator penetration. This study suggests a new design for collimator in Bremsstrahlung imaging which weighs less than half of usual collimators. This design will somewhat influence the resolution and sensitivity. Furthermore, the effect of wiener filter in Bremsstrahlung imaging is also considered
Material and Methods: Layer collimator in forms of digital phantom was designed by GATE simulator and its sensitivity and resolution in deferent layers was evaluated.
Results: By increasing collimator layers, sensitivity rose by 9%, in contrast, due to penetration resolution decreased to 11%. Furthermore, we did not find any evidence that showed wiener filter in Bremsstrahlung imaging improved resolution.
Conclusion: In this study, layer collimator has increased the sensitivity, consequently, the time required for collecting count for Bremsstrahlung imaging has decreased.

</abstract>
	<keyword_fa>پزشکی هسته‌ای, مونت‌کارلو, کولیماتور, تابش ترمزی, فسفر 32</keyword_fa>
	<keyword>Nuclear medicine, Monte Carlo, Collimator, Bremsstrahlung, Phosphorus 32</keyword>
	<start_page>23</start_page>
	<end_page>31</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-29-204&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Hadi</first_name>
	<middle_name></middle_name>
	<last_name>TaleshiAhangari</last_name>
	<suffix></suffix>
	<first_name_fa>هادی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>طالشی آهنگری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460038963</code>
	<orcid>100319475328460038963</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>PhD Student in Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran</affiliation>
	<affiliation_fa>علوم پزشکی مازندران</affiliation_fa>
	 </author>


	<author>
	<first_name> Hossein</first_name>
	<middle_name></middle_name>
	<last_name> Rajabi</last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رجبی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hrajabi@modares.ac.ir</email>
	<code>100319475328460038964</code>
	<orcid>100319475328460038964</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Associate Professor, Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran</affiliation>
	<affiliation_fa>علوم پزشکی مازندران</affiliation_fa>
	 </author>


	<author>
	<first_name> Mohammad</first_name>
	<middle_name></middle_name>
	<last_name>Eftekhari</last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>افتخاری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460038965</code>
	<orcid>100319475328460038965</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Professor, Research Institute for Nuclear Medicine, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>علوم پزشکی مازندران</affiliation_fa>
	 </author>


	<author>
	<first_name>Fariba</first_name>
	<middle_name></middle_name>
	<last_name>Johari Daha</last_name>
	<suffix></suffix>
	<first_name_fa> فریبا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa> جوهری دها</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460038966</code>
	<orcid>100319475328460038966</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>4 Assistant Professor, Department of Radioisotope, Nuclear Science and Technology Research Institute, Tehran, Iran</affiliation>
	<affiliation_fa>علوم پزشکی مازندران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
