<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>24</volume>
<number>116</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی امکان تشخیص اتوماتیک میکروکلسیم های بافت پستان با استفاده از تکنیک دو انرژی تصویربرداری اشعه ایکس جهت تشخیص زودرس سرطان پستان</title_fa>
	<title>Automatic Detection of Micro-Calcification in Breast Tissue by X-Ray Dual-energy Technique for Early Detection of Breast Cancer </title>
	<subject_fa>رادیولوژی </subject_fa>
	<subject>Psychiatric Nursing</subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>سابقه و هدف: ماموگرافی دوانرژی از تکنیک‌هایی است که برای بالا بردن دقت تشخیص سرطان پستان به خصوص در موارد پستان‌های چگال، هم چنین تشخیص میکروکلسیم‌ها که از علائم زودرس سرطان پستان است؛ به کار می‌رود. هدف از انجام این پژوهش، امکان سنجی جداسازی اتوماتیک تصاویر میکروکلسیم‌های بافت پستان و هم چنین ارزیابی دقت آن با استفاده از به کارگیری تکنیک تصویربرداری دیجیتال دو انرژی می‌باشد.
مواد و روش ها: در جهت دستیابی به اهداف تعریف شده تحقیق، یک فانتوم معادل پستان بر اساس ضرایب تضعیف پرتوی ایکس مواد تشکیل دهنده بافت پستان طراحی و ساخته شد و از ضخامت‌های مختلف آلومینیوم جهت شبیه‌سازی میکروکلسیم‌ها به وسیله یک تیوب اشعه ایکس با آند تنگستن و یک آشکارساز صفحه تخت از جنس Si/GadOxتصویربرداری شد. هم چنین در جهت به‌کارگیری از تکنیک تصویربرداری دوانرژی، فیلتر مناسب برای تولید طیف پرانرژی با استفاده از کد مونت کارلوی MCNP-4C طراحی و ساخته شد و از نرم افزار MATLAB برای حل معادله تخمین ضخامت مواد و انجام فرآیندهای پردازش تصویر مورد نیاز استفاده شد.
یافته ها: با استفاده از تکنیک به کارگیری شده، امکان جداسازی تصاویر آلومینیوم با ضخامت‌های بالاتر از 200 میکرومتر یا به عبارت دیگر میکروکلسیم‌های بالاتر از 235 میکرومتراز بافت غیر یکنواخت معادل پستان فراهم آمد.
استنتاج: با توجه به نتایج به دست آمده و هم چنین ابزار کار که بسیار مشابه به سیستم های رادیولوژی دیجیتال رایج است، می‌توان نتیجه گرفت تصویربرداری از پستان با به کارگیری تکنیک دو انرژی و با استفاده از فیلترهای مناسب این تکنیک، می‌تواند جهت تشخیص اتوماتیک میکروکلسیم‌های بافت پستان با ضخامت بالاتر از 235 میکرون به کار رفته و در تشخیص سرطان پستان در مراحل اولیه آن به پزشک معالج کمک نماید.
</abstract_fa>
	<abstract>Background and purpose: Dual-energy mammography technique is used for improving the accuracy of breast cancer diagnosis especially in dense breast cases and also detection of micro-calcifications which are early signs of breast cancer. The purpose of this study was to investigate the automatic separation feasibility of micro-calcification images in breast tissue images and evaluating its accuracy using digital dual-energy mammography technique.
Material and Methods: In this study, a breast phantom was designed and built based on X-ray attenuation of breast tissue components. Various thicknesses of Aluminum sheets were imaged for micro-calcification simulation by an X-ray tube with Tungsten anode and a flat panel detector which was made of Si/GadOx. In addition, to use Dual-energy imaging technique, appropriate filter for high-energy spectra was designed and built by MCNP-4C Monte Carlo code. Image processing and solving the thickness equations was done by MATLAB software.
Results: The applied technique achieved Al separation with thicknesses greater than 200 micron in the images. In other words, this technique could separate micro-calcium larger than 235 mm from non-uniform tissue of equivalent breast.
Conclusion: According to the results and the method which was used in this study that is very similar to the common digital radiology systems, breast imaging can be employed for automatic detection of micro-calcifications larger than 235 mm in breast tissue by using Dual-energy technique and its appropriate filters, thereby helping the physicians in early stages of detection.

</abstract>
	<keyword_fa>ماموگرافی دو انرژی, تشخیص میکروکلسیم‌های پستان, سرطان پستان</keyword_fa>
	<keyword>Dual energy mammography, micro- calcification detection, breast cancer</keyword>
	<start_page>11</start_page>
	<end_page>22</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-29-209&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>MohammadMahdi</first_name>
	<middle_name></middle_name>
	<last_name> Mojorad Kahani</last_name>
	<suffix></suffix>
	<first_name_fa>محمد مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مجرد کاهانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>kasra2m2002@yahoo.com</email>
	<code>100319475328460039043</code>
	<orcid>100319475328460039043</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>علوم پزشکی مازندران</affiliation>
	<affiliation_fa>علوم پزشکی مازندران</affiliation_fa>
	 </author>


	<author>
	<first_name>Alireza</first_name>
	<middle_name></middle_name>
	<last_name>Kamali</last_name>
	<suffix></suffix>
	<first_name_fa> علیرضا </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa> کمالی اصل</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460039044</code>
	<orcid>100319475328460039044</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>علوم پزشکی مازندران</affiliation>
	<affiliation_fa>علوم پزشکی مازندران</affiliation_fa>
	 </author>


	<author>
	<first_name>Samaneh </first_name>
	<middle_name></middle_name>
	<last_name> Hashemi</last_name>
	<suffix></suffix>
	<first_name_fa> سمانه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هاشمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460039045</code>
	<orcid>100319475328460039045</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>علوم پزشکی مازندران</affiliation>
	<affiliation_fa>علوم پزشکی مازندران</affiliation_fa>
	 </author>


	<author>
	<first_name> Hossein</first_name>
	<middle_name></middle_name>
	<last_name>Ghadiri</last_name>
	<suffix></suffix>
	<first_name_fa> حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قدیری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460039046</code>
	<orcid>100319475328460039046</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>علوم پزشکی مازندران</affiliation>
	<affiliation_fa>علوم پزشکی مازندران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
