<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1386</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2008</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>17</volume>
<number>62</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه اندازه گیری فشارخون توسط گوشی معمولی با گوشی تلفیقی</title_fa>
	<title>Accuracy of double stethoscope device for blood pressure evaluation</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify direction: rtl&quot;&gt;
&lt;span style=&quot;font-weight: bold&quot;&gt;سابقه و هدف:&lt;/span&gt; اندازه گیری دقیق فشارخون به عنوان شاخص مهم حیاتی در بخش های مختلف بالینی اهمیت زیادی دارد. یکی از مهم ترین و شایع ترین روش های اندازه گیری فشارخون با استفاده از روش غیرمستقیم با کاف فشار سنج و گوشی پزشکی می باشد. خطای انسانی و صحت انجام کار توسط دانشجویان گروه پزشکی در این روش مورد تردید است. لذا مطالعه حاضر به منظور تعیین دقت گوشی پزشکی تلفیقی درمقایسه با روش معمول و استاندارد گوشی پزشکی معمولی توسط استاد، انجام شد.&lt;br&gt;&lt;span style=&quot;font-weight: bold&quot;&gt;مواد و روش ها:&lt;/span&gt; در یک مطالعه تشخیصی، با رعایت موارد استاندارد، فشارخون سیستول و دیاستول 65 نفر از دانشجویان پرستاری داوطلب در وضعیت نشسته در دو مرحله با فاصله زمانی ده دقیقه، اندازه گیری شد. مرحله اول فشارخون از دست چپ با استفاده از گوشی تلفیقی توسط استاد و کارشناس، اندازه گیری و ثبت گردید و سپس بعد از پنج دقیقه فشارخون به روش استاندارد با استفاده از گوشی معمولی توسط استاد اندازه گیری و ثبت شد. همبستگی نتایج با استفاده از ضریب همبستگی پیرسون تعیین گردید.&lt;br&gt;&lt;span style=&quot;font-weight: bold&quot;&gt;یافته ها: &lt;/span&gt;میانگین فشارخون سیستول و دیاستول با استفاده ازفشار سنج جیوه ای به روش استاندارد به ترتیب 11.3±1.1 و 7.5±1.1 بود و این فشارخون با استفاده ازگوشی تلفیقی توسط استاد و کارشناس مربوطه به ترتیب (11.2±1.2 و 7.4±1.2) و (11.1±1.2 و 7.2±1.1) بوده است. محاسبه فشارخون با روش های مختلف با هم هم خوانی داشته و میزان هبستگی آنان بالا بود.&lt;br&gt;&lt;span style=&quot;font-weight: bold&quot;&gt;استنتاج:&lt;/span&gt; استفاده از گوشی تلفیقی برای اندازه گیری فشارخون سیستول و دیاستول، روش مناسبی می باشد.
&lt;/div&gt;</abstract_fa>
	<abstract>
&lt;span style=&quot;font-weight: bold&quot;&gt;Background and Purpose:&lt;/span&gt; Blood pressure (BP) is routinely evaluated intermittently during the clinical status for care and treatment. The most common method to measure BP is by using the sphygmomanometer with a stethoscope. This method may be difficult for medical students that will use BP for medical evaluation. The purpose of this study was to compare the accuracy of double stethoscope device for blood pressure monitoring, with standard ausculatory measurements using a mercury sphygmomanometer.
&lt;br&gt;&lt;span style=&quot;font-weight: bold&quot;&gt;Materials and Methods:&lt;/span&gt;In this distinguished report, 65 volunteer participants were studied. Means, standard deviations and Systolic, Diastolic pressure were calculated. The correlation between groups was determined with Pearson correlation.
&lt;br&gt;&lt;span style=&quot;font-weight: bold&quot;&gt;Results:&lt;/span&gt;Mean difference in systolic, Diastolic Blood pressure between standard and routine method with double stethoscope method measurements, was not significant (P&lt;0.001) and were in agreement with Pearson correlation between them.
&lt;br&gt;&lt;span style=&quot;font-weight: bold&quot;&gt;Conclusion:&lt;/span&gt;This study demonstrates that the double stethoscope device provides an accurate measure of blood pressure that is closely approximates with what is achieved by the indirect auscultator method, using a mercury sphygmomanometer.
</abstract>
	<keyword_fa>اندازه گیری فشارخون، گوشی تلفیقی یا دوگانه، دقت، مانیتورینگ</keyword_fa>
	<keyword>Blood pressure measurement, Double stethoscope, Accuracy, Monitoring</keyword>
	<start_page>49</start_page>
	<end_page>53</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-1-456&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>A</first_name>
	<middle_name></middle_name>
	<last_name>Amiri</last_name>
	<suffix></suffix>
	<first_name_fa>انسیه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امیری </last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846005697</code>
	<orcid>10031947532846005697</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>E</first_name>
	<middle_name></middle_name>
	<last_name>Nasiri</last_name>
	<suffix></suffix>
	<first_name_fa>ابراهیم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نصیری </last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846005698</code>
	<orcid>10031947532846005698</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>R.A</first_name>
	<middle_name></middle_name>
	<last_name>Mouhammadpour</last_name>
	<suffix></suffix>
	<first_name_fa>رضاعلی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محمدپور تهمتن </last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846005699</code>
	<orcid>10031947532846005699</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
