<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2015</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>24</volume>
<number>122</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی میزان دقت جداسازی تصاویر دو ماده حاجب مختلف به صورت همزمان از بافت پستان با استفاده از تکنیک ماموگرافی دیجیتال دو انرژی</title_fa>
	<title>Simultaneous Use of Two Different Contrast Agents and Assessing their Accuracy in Breast Tissue Using Dual-Energy Digital Mammography</title>
	<subject_fa>ژنتیک</subject_fa>
	<subject>genetic</subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>سابقه و هدف: ماموگرافی دوانرژی از تکنیک‌هایی است که برای بالا بردن دقت تشخیص سرطان پستان مخصوصا در پستان‌های چگال به کار می‌رود. هدف از انجام این پژوهش، استفاده هم زمان از دو ماده حاجب و ارزیابی میزان دقت جداسازی تصاویر دو ماده حاجب به کار رفته با استفاده از تکنیک ماموگرافی دیجیتال دو انرژی می‌باشد.
مواد و روش‌ها: فانتومی معادل بافت پستان طراحی و ساخته شد. از ضخامت‌های مختلف آلومینیوم جهت شبیه‌سازی میکروکلسیم‌های بافت پستان استفاده و هم چنین دو ماده حاجب ید و بیسموت با ضخامت چگالشی‌های متفاوت در آن قرارداده شد. به وسیله یک تیوب اشعه ایکس با آند تنگستن و یک آشکارساز صفحه تخت از جنس Si/GadOx تصویربرداری‌ها انجام شد. هم چنین جهت به‌کارگیری از تکنیک تصویربرداری دوانرژی، فیلتر مناسب برای تولید طیف پرانرژی با استفاده از کد مونت کارلوی MCNP-4C طراحی و ساخته و از نرم افزار MATLAB برای حل معادلات و انجام فرآیندهای پردازش تصویر مورد نیاز استفاده شد.
یافته‌ها: ماده حاجب ید با ضخامت چگالشی بالاتر از  mg/cm25/0 و ماده حاجب بیسموت با ضخامت بالاتر از mg/cm2 53/0 از فانتوم معادل بافت پستان جداگردید
استنتاج: با به کارگیری تکنیک ماموگرافی دیجیتال دو انرژی و انتخاب مواد حاجب با مشخصات مناسب و به کارگیری روش‌های پردازش تصویر درخور، امکان جداسازی هم زمان تصاویر دو ماده حاجب ید و بیسموت از بافت پستان با دقت خوبی فراهم آمد، در حالی که به کارگیری این روش و اطلاعات به دست آمده از آن می تواند به سهولت و دقت تشخیص پزشک کمک کند.



</abstract_fa>
	<abstract>
Background and purpose: Dual-energy mammography is a technique which is used to enhance the accuracy of breast cancer diagnosis especially in dense breasts. This study was conducted based on the simultaneous use of two contrast agents for automatic separation and also to evaluate their accuracy using dual-energy digital mammography. 
Materials and methods: A breast phantom was designed and built. Different thicknesses of aluminum sheets were imaged for micro-calcification simulation and Iodine and Bismuth contrast agents were placed at various density thicknesses inside the phantom. Also, an X-ray tube with Tungsten anode and a flat panel semiconductor detector Si/GadOx was used for imaging processes. To apply dual-energy imaging, appropriate filter for high-energy spectrum was designed by MCNP-4C Monte Carlo code and built. Matlab software was used for equations solving and image processing.
Results: The separation of Iodine images was prepared for thicknesses greater than 0.5 mg/cm2and Bismuth images greater than 0.53 mg/cm2.
Conclusion: According to the results, simultaneous isolation of two contrast agent images, I and Bi, from breast tissue were accurately prepared by dual-energy digital mammography via choosing appropriate contrast agent materials and image processing technique. So, this method could help the physicians in making an easy and more accurate diagnosis. 



</abstract>
	<keyword_fa>ماموگرافی دو انرژی, تکنیک پردازش تصویر, جداسازی اتوماتیک مواد حاجب, سرطان پستان</keyword_fa>
	<keyword>Dual-energy mammography, image processing technique, contrast agent automatic detection, breast cancer</keyword>
	<start_page>239</start_page>
	<end_page>251</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-29-271&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammad Mahdi</first_name>
	<middle_name></middle_name>
	<last_name>Mojorad Kahani</last_name>
	<suffix></suffix>
	<first_name_fa>محمد مهدی </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مجرد کاهانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m_kahani@sbu.ac.ir</email>
	<code>100319475328460052152</code>
	<orcid>100319475328460052152</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>MSc in Medical Radiation, Faculty of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran</affiliation>
	<affiliation_fa>کارشناس ارشد مهندسی هسته ای، دانشکده مهندسی هسته ای، دانشگاه شهید بهشتی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name> Alireza</first_name>
	<middle_name></middle_name>
	<last_name> KamaliAsl</last_name>
	<suffix></suffix>
	<first_name_fa>  علیرضا </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کمالی اصل</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460052153</code>
	<orcid>100319475328460052153</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Department of Medical Radiation Engineering, Faculty of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran</affiliation>
	<affiliation_fa>دانشیار، گروه پرتوپزشکی، دانشکده مهندسی هسته ای، دانشگاه شهید بهشتی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Samaneh</first_name>
	<middle_name></middle_name>
	<last_name>Hashemi</last_name>
	<suffix></suffix>
	<first_name_fa> سمانه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هاشمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460052154</code>
	<orcid>100319475328460052154</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc in Medical Radiation, Faculty of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran</affiliation>
	<affiliation_fa>کارشناس ارشد مهندسی هسته ای، دانشکده مهندسی هسته ای، دانشگاه شهید بهشتی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hossein</first_name>
	<middle_name></middle_name>
	<last_name>Ghadiri</last_name>
	<suffix></suffix>
	<first_name_fa>حسین </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قدیری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460052155</code>
	<orcid>100319475328460052155</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>استادیار، گروه فیزیک پزشکی،دانشگاه علوم پزشکی تهران ، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name> Hossein</first_name>
	<middle_name></middle_name>
	<last_name>Ghadiri</last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa> انتظار مهدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460052156</code>
	<orcid>100319475328460052156</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>PhD Student in Medical Radiation, Faculty of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran</affiliation>
	<affiliation_fa>دانشجوی دکتری مهندسی هسته ای، دانشکده مهندسی هسته ای، دانشگاه شهید بهشتی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>جمال</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خم خاجی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460052157</code>
	<orcid>100319475328460052157</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>PhD Student in Medical Radiation, Faculty of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran</affiliation>
	<affiliation_fa>دانشجوی دکتری مهندسی هسته ای، دانشکده مهندسی هسته ای، دانشگاه شهید بهشتی تهران، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
