<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2015</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>24</volume>
<number>122</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی اثر بیس پلیت غیر فیبر کربنی بر دز پوست در پرتودرمانی سرطان پستان با استفاده از فیلم گاف‌کرومیک EBT2</title_fa>
	<title>The Effect of Non-carbon Fiber Base Plates on Skin Dose Increase in Radiotherapy of Breast Cancer Using Gaf-Chromic Films</title>
	<subject_fa>ژنتیک</subject_fa>
	<subject>genetic</subject>
	<content_type_fa>گزارش کوتاه</content_type_fa>
	<content_type>Brief Report</content_type>
	<abstract_fa>سابقه و هدف: بیس پلیت های غیرفیبرکربنی (به عنوان وسیله کمک درمانی) که در رادیوتراپی بعضی از نواحی به ویژه در درمان سرطان پستان استفاده می‌شوند، به دلیل ایجاد پرتوهای پراکنده می‌تواند در میزان دز نواحی سطحی بدن و پوست تاثیرگذار باشد. اخیراً با استفاده از فیلم گاف کرومیک نتایج خوبی در دزیمتری پوست به دست آمده است. هدف از این مطالعه برآورد میزان تغییرات دز پوست در به کارگیری بیس پلیت‌های غیر فیبر کربنی در درمان سرطان پستان با استفاده از فیلم گاف کرومیک و فانتوم بوده است.
مواد و روش‌ها: در مطالعه تجربی حاضرابتدا در مدهای فوتونی 6 و 15 مگاولتی شتاب دهنده الکترونی زیمنس مدل پریموس، منحنی کالیبراسیون برای فیلم‌ها رسم گردید. برای تهیه منحنی کالیبراسیون از دزیمتر صفحه موازی Roos استفاده شد. برای اندازه‌گیری اثر بیس پلیت، فیلم‌ها در کف یک فانتوم آب 30×30 ×30 (برحسب سانتی‌متر) چسبانده شدند و در مدهای فوتونی ذکر شده در حالت حضور و عدم حضور بیس پلیت تحت تابش قرار گرفتند.
یافته‌ها: منحنی کالیبراسیون در هر دو انرژی 6 و 15 مگاولتی با دو تابع خطی (به ترتیب با 996/0R²= و 995/0R²=) به خوبی قابل برازش بود. درصد اختلاف بین حالت‌های با و بدون حضور بیس پلیت برای مدهای فوتونی 6 و 15 مگاولت به ترتیب 56/16درصد و 27/5درصد به دست آمد.
استنتاج: در پرتودرمانی سرطان پستان، بیس پلیت غیر فیبر کربنی دز پوست ناحیه خلف سوپراکلاو را افزایش می‌دهد. این میزان افزایش در انرژی 6 مگاولتی قابل توجه تر از انرژی 15 مگاولتی است.

</abstract_fa>
	<abstract>Background and purpose: Due to creation of scattered radiation when using non-carbon fiber base plates particularly in treating breast cancer, applying this device can affect skin and body surface dose. Recently, using Gaf-Chromic films have led to obtaining good results in skin dosimetry. The purpose of this study was the estimation of skin dose in applying non-carbon fiber base plates using water phantom and Gaf-chromic films.
Materials and methods: In an experimental study, calibration curves in 6 and 15 MV photon mode of operation of a Siemens Primus were derived for the EB2 Gaf-Chromic films. To obtain these curves parallel plate Roos dosimeter was utilized. To measure the effect of non-carbon fiber base plate, films were attached to the bottom of a 30×30×30 cm3 water phantom and were exposed in two different energies with and without placing the non-carbon fiber base plate on the Linac coach.
Results: Calibration curves for both energies were fairly correlated to linear functions. Percentage difference for the mentioned situations (with and without using base plate) for 6 and 15 MV energies were 16.56% and 5.27%, respectively.
Conclusion: In breast cancer radiation therapy, applying non-carbon fiber base plate, can increase the skin dose in posterior supraclavicular field. In this study the increase was more pronounced in 6 MV energy than 15 MV. 





</abstract>
	<keyword_fa>بیس پلیت غیر فیبر کربنی, دز پوست, شتاب دهنده خطی, سرطان پستان</keyword_fa>
	<keyword>Non-carbon fiber base plate, skin dose, Linac, breast cancer</keyword>
	<start_page>339</start_page>
	<end_page>344</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-29-331&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Arash</first_name>
	<middle_name></middle_name>
	<last_name> Ghasemi</last_name>
	<suffix></suffix>
	<first_name_fa>آرش </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قاسمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460052378</code>
	<orcid>100319475328460052378</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Radiology, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran</affiliation>
	<affiliation_fa>استادیار، گروه رادیولوژی، دانشکده پزشکی، دانشگاه علوم پزشکی مازندران، ساری، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Tayyeb</first_name>
	<middle_name></middle_name>
	<last_name>Allahverdi Pourfallah</last_name>
	<suffix></suffix>
	<first_name_fa>طیب</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>الهویردی پورفلاح</last_name_fa>
	<suffix_fa></suffix_fa>
	<email> tpourfallah@gmail.com</email>
	<code>100319475328460052379</code>
	<orcid>100319475328460052379</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Assistant Professor, Department of Biochemistry and Biophysics, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran</affiliation>
	<affiliation_fa>استادیار، گروه بیوشیمی بیوفیزیک، دانشکده پزشکی، دانشگاه علوم پزشکی مازندران، ساری، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mahmoodreza</first_name>
	<middle_name></middle_name>
	<last_name>Akbari</last_name>
	<suffix></suffix>
	<first_name_fa>   محمود رضا </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اکبری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460052380</code>
	<orcid>100319475328460052380</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc in Medical Radiation, Nuclear Sciences and Technology Research Institute, Tehran, Iran</affiliation>
	<affiliation_fa>کارشناس ارشد پرتوپزشکی، انستیتو تحقیقات تکنولوژی و علوم هسته ای، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
