<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1394</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2015</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>25</volume>
<number>131</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی خون سازگاری سطح اپی تلیال پرده آمنیون در مقایسه با رگ صناعی (پلی تترافلورواتیلن)</title_fa>
	<title>Evaluation of Blood Compatibility of Amnion Epithelial Side Compared to Artificial Vessel (Polytetrafluoroethylene)</title>
	<subject_fa> بافت شناسي</subject_fa>
	<subject>histology</subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;سابقه و هدف: پرده آمنیون یکی از داربست‌های مناسب جهت استفاده در مهندسی بافت عروق می‌باشد. این مطالعه با هدف ارزیابی خون سازگاری سطح اپی‌تلیال پرده آمینون و مقایسه با رگ صناعی انجام شده است.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;مواد و روش‌ها: در مطالعه تجربی حاضر تاثیر سطح اپی‌تلیال پرده آمنیون بر روی آزمون‌های انعقاد خون شامل زمان پروترومبین &lt;span dir=&quot;LTR&quot;&gt;(PT)&lt;/span&gt;، زمان پارشیال ترومبوپلاستین &lt;span dir=&quot;LTR&quot;&gt;(aPTT)&lt;/span&gt;، زمان تشکیل لخته &lt;span dir=&quot;LTR&quot;&gt;(CT)&lt;/span&gt;، همولیز و تجمع پلاکتی در مقایسه با پلی‌تترافلورواتیلن انبساطی (&lt;span dir=&quot;LTR&quot;&gt;ePTFE&lt;/span&gt;) مورد بررسی قرار گرفت. جهت بررسی میزان فعال شدن پلاکت‌ها مقادیر &lt;span dir=&quot;LTR&quot;&gt;p-selectin&lt;/span&gt; آزاد شده پس از تماس با سطح اپی تلیال پرده آمنیون به روش الایزا اندازه‌گیری شد. هم‌چنین میزان چسبندگی و تغییر مورفولوژی پلاکت‌ها توسط میکروسکوپ الکترونی مورد ارزیابی قرار گرفت.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;یافته‌ها: نتایج آزمون‌های &lt;span dir=&quot;LTR&quot;&gt;PT&lt;/span&gt;، &lt;span dir=&quot;LTR&quot;&gt;aPTT&lt;/span&gt; و &lt;span dir=&quot;LTR&quot;&gt;CT&lt;/span&gt; در این مطالعه نشان دادند که سطح اپی‌تلیال پرده آمنیون مسیر خارجی انعقاد را کم تر از &lt;span dir=&quot;LTR&quot;&gt;ePTFE&lt;/span&gt; فعال می‌کند و هم‌چنین اثر مشابهی با &lt;span dir=&quot;LTR&quot;&gt;ePTFE&lt;/span&gt; در فعال کردن مسیر داخلی انعقاد دارد. هم‌چنین سطح اپی‌تلیال پرده آمنیون مانع از تجمع، فعال شدن و اتصال پلاکت‌ها به آن می‌شود در حالی که تعداد پلاکت‌های متصل به &lt;span dir=&quot;LTR&quot;&gt;ePTFE&lt;/span&gt; بیش‌تر بود.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;استنتاج: با توجه به خواص ویژه پرده آمنیون و یافته‌های امیدوارکننده‌ای که از آزمون‌های خون سازگاری سطح اپی تلیال پرده آمنیون در این مطالعه به دست آمده است، این پرده می‌تواند جایگزین مناسبی جهت استفاده در مهندسی بافت عروق باشد.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and purpose:&lt;/strong&gt; Amniotic membrane (AM) is a proper candidate for vascular tissue engineering. The aim of this study was to evaluate the hemocompatibility of the epithelial surface of the AM.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Materials and methods:&lt;/strong&gt; In this study, we assessed the effects of the epithelial surface of&lt;br&gt;
the AM on blood coagulation system by measuring activated partial thromboplastin time (aPTT), prothrombin time (PT), clotting time (CT), hemolysis and platelet aggregation compared with expanded Polytetrafluoroethylene (ePTFE). The amount of P-selectin was measured to test the platelet activation using ELISA. Adhesion and morphological changes of platelets were analyzed by scanning electron microscopy. &lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; The results of aPTT, PT and CT tests showed that the epithelial surface of the AM activated the external coagulation pathway less than ePTFE and had same effects as this synthetic material on the internal coagulation pathway. Furthermore, the epithelial surface of the AM suppressed aggregation, activation and adhesion of the platelets and in turn inhibited initiation of clot formation. In contrast, more number of platelets were adhered and activated on the surface of ePTFE.  &lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Based on suitable features of the AM and hemocompatibility results of amniotic epithelial cells which have stem cell characteristics, the AM could be a good candidate for vascular tissue engineering.&lt;/p&gt;
</abstract>
	<keyword_fa>پرده آمنیون, خون سازگاری, مهندسی بافت, ePTFE</keyword_fa>
	<keyword>Amniotic membrane, hemocompatibility, tissue engineering, ePTFE</keyword>
	<start_page>67</start_page>
	<end_page>78</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-5029-138&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mona</first_name>
	<middle_name></middle_name>
	<last_name>Kakavand</last_name>
	<suffix></suffix>
	<first_name_fa>مونا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کاکاوند</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>General Practitioner, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>پزشک عمومی، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Ghasem</first_name>
	<middle_name></middle_name>
	<last_name>Yazdanpanah</last_name>
	<suffix></suffix>
	<first_name_fa>قاسم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یزدان پناه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>General Practitioner, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>پزشک عمومی، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hassan</first_name>
	<middle_name></middle_name>
	<last_name>Niknejad</last_name>
	<suffix></suffix>
	<first_name_fa>حسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نیک ‏نژاد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>niknejad@sbmu.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>2Associate Professor, Department of Tissue Engineering and Regenerative Medicine, School of Advanced Technologies in Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran  3 Nanomedicine and Tissue Engineering Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>دانشیار، گروه مهندسی بافت و طب بازساختی، دانشکده فناوری های نوین پزشکی، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران 3. مرکز تحقیقات نانوتکنولوژی پزشکی و مهندسی بافت، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
