<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>137</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>اثر ناهمگنی بر صحت دزیمتری در پرتودرمانی کانفورمال پروستات با استفاده از شبیه سازی مونت کارلو </title_fa>
	<title>Effect of Tissue Inhomogeneities on Dosimetric Accuracy of Conformal Radiotherapy of Prostate Cancer Using  Monte Carlo Simulation</title>
	<subject_fa>فیزیک پزشکی</subject_fa>
	<subject>Medical physics</subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;سابقه و هدف: بدن انسان از بافت&#8204;های متنوع ناهمگنی با خصوصیات فیزیکی و رادیولوژیکی متفاوت تشکیل شده است. توزیع دز به واسطه وجود این ناهمگنی&#8204;ها تغییر می&#8204;کند و در میدان&#8204;های کانفورمال، احتمال خطای هندسی در تابش تومور به دلیل عدم قطعیت ناشی از اثر ناهمگنی در منحنی&#8204;های هم&#8204;دز، افزایش می&#8204;یابد. در این تحقیق، اثر ناهمگنی بر صحت دزیمتریکی سیستم طراحی درمان &lt;span dir=&quot;LTR&quot;&gt;CorPLAN&lt;/span&gt; در پرتودرمانی کانفورمال پروستات با استفاده از روش شبیه سازی مونت کارلو بررسی شده است.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;مواد و روش&#8204;ها: در این مطالعه تجربی، از دو فانتوم انسان&#8204;گونه همگن و ناهمگن لگن هندسی کاملاً شبیه به هم برای اندازه&#8204;گیری&#8204;های تجربی و محاسباتی استفاده شد. طراحی درمان کانفورمال سه&#8204;بعدی (&lt;span dir=&quot;LTR&quot;&gt;3DCRT&lt;/span&gt;) پنج میدانی بر روی تصاویر &lt;span dir=&quot;LTR&quot;&gt;CT&lt;/span&gt; این فانتوم&#8204;ها در انرژی&#8204;های 6 و18 مگاولت با استفاده ازسیستم طراحی درمان تجاری &lt;span dir=&quot;LTR&quot;&gt;(CorPLAN)&lt;/span&gt; موجود در دستگاه شتاب&#8204;دهنده خطی واریان مدل &lt;span dir=&quot;LTR&quot;&gt;2100C/D&lt;/span&gt; انجام شد. همین نوع طراحی درمان برای همان شرایط به کار رفته در برنامه &lt;span dir=&quot;LTR&quot;&gt;CorePLAN&lt;/span&gt; با استفاده از کد مونت&#8204;کارلوی &lt;span dir=&quot;LTR&quot;&gt;EGSnrc&lt;/span&gt; نیز شبیه سازی شد. توزیع دز به&#8204;دست آمده از شبیه&#8204;سازی مونت&#8204;کارلو با توزیع دز حاصل از سیستم طراحی درمان برای هر دو فانتوم بر مبنای پارامترهای میانگین &amp;quot;درصد اختلاف دز&amp;quot; و &amp;quot;فاصله تا توافق&amp;quot; مقایسه شدند&lt;span dir=&quot;LTR&quot;&gt;.&lt;/span&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;یافته&#8204;ها: نتایج نشان می&#8204;دهد وجود ناهمگنی، سبب افزایش دز حاصل از الگوریتم به کار رفته در سیستم طراحی درمان &lt;span dir=&quot;LTR&quot;&gt;(CorPLAN)&lt;/span&gt; تا 8/2 درصد و 4/4 درصد به ترتیب برای انرژی 6 و 18 مگاولت نسبت به مونت کارلو شده است. میانگین مقادیر &lt;span dir=&quot;LTR&quot;&gt;DD&lt;/span&gt; و &lt;span dir=&quot;LTR&quot;&gt;DTA&lt;/span&gt; برای فانتوم همگن 7/2-&lt;span dir=&quot;LTR&quot;&gt;mm&lt;/span&gt; 4/3 درصد و 6/1-&lt;span dir=&quot;LTR&quot;&gt;mm&lt;/span&gt; 3/2 درصد به ترتیب برای انرژی&#8204;های 6 و 18 مگاولت و برای فانتوم همگن 5/5-&lt;span dir=&quot;LTR&quot;&gt;mm&lt;/span&gt; 7/3 درصد و 0/6-&lt;span dir=&quot;LTR&quot;&gt;mm&lt;/span&gt; 5/2 درصد در انرژی های مذکور بود.&lt;/p&gt;

&lt;p&gt;&lt;span dir=&quot;RTL&quot;&gt;استنتاج: &lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;صحت &lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;تخمین پارامترهای &lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;دزیمتری&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt; توسط&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt; سیستم طراحی درمان &lt;/span&gt;CorPLAN &lt;span dir=&quot;RTL&quot;&gt;در انرژی&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&#8204;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;های 18 مگاولت بیش&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&#8204;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;تر از مقادیر مربوط در انرژی 6 مگاولتی بود. لیکن، وجود ناهمگنی موجب &lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;کاهش &lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;بیش&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&#8204;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;تری در &lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;مقدار &lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;صحت &lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;پارامترهای &lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;دزیمتری &lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;برآورد شده توسط این سیستم طراحی درمان تجاری &lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;در انرژی 18 مگاولت می&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&#8204;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;شود.&lt;/span&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and purpose:&lt;/strong&gt; The human body is composed of various inhomogenous tissues with a variety of physical and radiological properties. These inhomogeneities could change isodose distributions, increase the probability of geometric errors, and eventually lead to missing of the target irradiation or incorrect isodose coverage in conformal radiation therapy (CRT) due to the uncertainties resulted from the effect of such inhomogeneties on isodose curves. In this study, the effect of inhomogeneities on dosimetric accuracy of the CRT of prostate was investigated using Monte Carlo simulation method.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Materials and methods:&lt;/strong&gt; An anthropomorphic pelvis phantom was used in two modes representing a homogeneous and heterogeneous phantom. Three dimensional (3D) CRT planning composed of five fields were performed on the CT images of the phantoms using the CorPLAN treatment planning system (TPS) of a 2100C/D Varian linac. Delivery of 3DCRT was also simulated by EGSnrc Monte Carlo code for the same conditions used in the CorPLAN TPS. The dose distributions resulted from the MC simulations were compared with those of the CorPLAN TPS for both of the phantoms based on the &amp;quot;dose difference (DD) percentages&amp;quot; and &amp;quot;distance to agreement (DTA)&amp;quot; parameters.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results: &lt;/strong&gt;Findings indicated that the heterogeneity leads to an overdose estimation at the target location up to 2.8% and 4.4% for the 6 and 18 MV energies, respectively by the CorPLAN TPS compared with the MC simulation data. The average DD and DTA for the homogeneous phantom were 2.7%-3.4mm and 1.6%-2.3 mm while for the inhomogeneous phantom they were 5.5%-3.7 mm and 6.0%-2.5 mm at the 6 and 18 MV energies, respectively.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Our results indicates that the accuracy of the dosimetry parameters estimated by the CorPLAN TPS &lt;a name=&quot;OLE_LINK2&quot;&gt;&lt;/a&gt;&lt;a name=&quot;OLE_LINK1&quot;&gt;at 18 MV is more than that of 6 MV&lt;/a&gt; energy. But, the heterogeneity deteriorates more the accuracy level of such dosimetry parameters estimated by this commercial TPS at 18 MV energy.&lt;/p&gt;

&lt;p&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;&amp;nbsp;&lt;/p&gt;
</abstract>
	<keyword_fa>سرطان پروستات, پرتودرمانی کانفورمال, روش مونت کارلو, سیستم طراحی درمان</keyword_fa>
	<keyword>prostate cancer, conformal radiation therapy, Monte Carlo, treatment planning system</keyword>
	<start_page>137</start_page>
	<end_page>149</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-29-423&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mehdi</first_name>
	<middle_name></middle_name>
	<last_name> Elahi</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>الهی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460084797</code>
	<orcid>100319475328460084797</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc in Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran</affiliation>
	<affiliation_fa>کارشناسی ارشد فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه تربیت مدرس، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Bijan</first_name>
	<middle_name></middle_name>
	<last_name> Hashemi</last_name>
	<suffix></suffix>
	<first_name_fa>بیژن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هاشمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>bhashemi@modares.ac.ir</email>
	<code>100319475328460084798</code>
	<orcid>100319475328460084798</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation> Associate Professor, Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran </affiliation>
	<affiliation_fa>. دانشیار، گروه فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه تربیت مدرس، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyed Rabie</first_name>
	<middle_name></middle_name>
	<last_name> Mahdavi</last_name>
	<suffix></suffix>
	<first_name_fa>سید ربیع</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مهدوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460084799</code>
	<orcid>100319475328460084799</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>. دانشیار، گروه فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
