<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>138</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بهینه سازی حذف آفت کش دیازینون از محیط های آبی توسط فرایند انعقاد الکتریکی با استفاده از روش سطح پاسخ</title_fa>
	<title>Optimization of Diazinon Removal from Aqueous Environments by Electrocoagulation Process Using Response Surface Methodology</title>
	<subject_fa>بهداشت محیط زیست</subject_fa>
	<subject>Environmental Health</subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;سابقه و هدف: آفت&#8204;کش دیازینون یکی از پر مصرف&#8204;ترین سموم ارگانوفسفره بوده که سازمان جهانی بهداشت این آفت&#8204;کش را در زمره سموم با درجه خطر متوسط در کلاس &lt;span dir=&quot;LTR&quot;&gt;II&lt;/span&gt; طبقه&#8204;بندی کرده است. مطالعه حاضر با هدف بهینه&#8204;سازی فرآیند انعقاد الکتریکی در حذف آفت کش دیازینون از محیط&#8204;های آبی به روش سطح پاسخ انجام پذیرفت.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;مواد و روش&#8204;ها: بر مبنای یک مطالعه تجربی آزمایشگاهی به روش بهینه &lt;span dir=&quot;LTR&quot;&gt;D&lt;/span&gt;، بررسی تاثیر متغیرهای مستقل شامل غلظت آفت کش دیازینون (100-10 میلی&#8204;گرم در لیتر)، ولتاژ اعمال شده (40-20 ولت)، زمان واکنش (60-10 دقیقه) و &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; محلول (10-3) بر راندمان حذف دیازینون با تعداد 30 مرحله آزمایش انجام شد. بهینه سازی شرایط با استفاده از روش سطح پاسخ و تحلیل مدل پیشنهادی به روش آنالیز واریانس صورت پذیرفت.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;یافته&#8204;ها: مدل پیشنهادی برای میزان راندمان حذف دیازینون از نظر آماری در سطح اطمینان 95 درصد معنی&#8204;دار و ضعف برازش برای مدل پیشنهادی در سطح اطمینان 95 درصد بی&#8204;معنی بود (614/0&lt;span dir=&quot;LTR&quot;&gt;p=&lt;/span&gt;). راندمان حذف دیازینون تابع تغییرات غلظت اولیه، ولتاژ اعمال شده و زمان واکنش بود. هم&#8204;چنین راندمان حذف دیازینون در شرایط بهینه (&lt;span dir=&quot;LTR&quot;&gt;mg/l&lt;/span&gt; 100 و ولتاژ 20 ولت) برابر با 6/84 درصد تعیین گردید.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;استنتاج: فرایند انعقاد الکتریکی تحت شرایط آزمایشگاهی ذکر شده یک روش کارآمد برای حذف آفت&#8204;کش دیازینون از محلول&#8204;های آبی می&#8204;باشد. طراحی آزمایش به روش بهینه &lt;span dir=&quot;LTR&quot;&gt;D&lt;/span&gt; می&#8204;تواند به نحو مطلوبی فرایند حذف را بهینه&#8204;سازی نموده و با کاهش تعداد آزمایش ها بهترین شرایط حذف آلاینده را تامین نماید.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and purpose:&lt;/strong&gt; Diazinon is one of the most widely used organophosphate pesticides classified by the World Health Organization (WHO) as &amp;ldquo;moderately hazardous&amp;rdquo; Class II. This work aimed at optimizing the electrocoagulation process in removal of diazinon from aqueous environments using response surface methodology.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Materials and methods:&lt;/strong&gt; In an experimental-laboratory study using the D-optimal method, the effects of independent variables including initial concentration of diazinon (10-100 mg/l), applied voltage (20-40 V), reaction time (10-60 min) and pH (3-10) were investigated on removal of diazinon in 30 runs. Process optimization was done by response surface methodology. Analysis of proposed model was also performed using analysis of variance.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; Diazinon removal in proposed model was statistically significant at 95% confidence level. The model had insignificant lack-of-fit at 95% confidence level (P=0.614). Diazinon removal efficiency was dependent on initial concentration of diazinon, applied voltage, and reaction time. The removal efficiency of diazinon was 84.6% at optimum condition (voltage= 20 V and diazinon concentration= 100 mg/L).&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Electrocoagulation process applying current experimental conditions was found to be efficient in removal of diazinon from aqueous solutions. Designing experiments by D-optimal method can optimize the removal of the process and prepare the best conditions for pollutant removal by reducing the number of experiments.&lt;/p&gt;
</abstract>
	<keyword_fa>آفت کش, دیازینون, انعقاد الکتریکی, روش سطح پاسخ</keyword_fa>
	<keyword>pesticide, diazinon, electrocoagulation, response surface methodology</keyword>
	<start_page>118</start_page>
	<end_page>130</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-3397-69&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Edris</first_name>
	<middle_name></middle_name>
	<last_name>Bazrafshan</last_name>
	<suffix></suffix>
	<first_name_fa>ادریس</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بذرافشان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ed_bazrafshan@yahoo.com</email>
	<code>100319475328460086528</code>
	<orcid>100319475328460086528</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Professor, Department of Environmental Health, Health Promotion Research Center, Faculty of Health, Zahedan University of Medical Sciences, Zahedan, Iran</affiliation>
	<affiliation_fa>استاد، گروه بهداشت محیط، مرکز تحقیقات ارتقاء سلامت، دانشکده بهداشت، دانشگاه علوم پزشکی زاهدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Leili</first_name>
	<middle_name></middle_name>
	<last_name>Mohammadi</last_name>
	<suffix></suffix>
	<first_name_fa>لیلی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460086529</code>
	<orcid>100319475328460086529</orcid>
	<coreauthor>No</coreauthor>
	<affiliation> PhD by Research in Environmental Health, Health Promotion Research Center, Faculty of Health, Zahedan University of Medical Sciences, Zahedan, Iran </affiliation>
	<affiliation_fa>دانشجوی دکترای پژوهشی بهداشت محیط، مرکز تحقیقات ارتقاء سلامت، دانشکده بهداشت، دانشگاه علوم پزشکی زاهدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Davoud</first_name>
	<middle_name></middle_name>
	<last_name>Balarak</last_name>
	<suffix></suffix>
	<first_name_fa>داوود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بلارک</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460086530</code>
	<orcid>100319475328460086530</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc in Environmental Health, Health Promotion Research Center, Faculty of Health, Zahedan University of Medical Sciences, Zahedan, Iran</affiliation>
	<affiliation_fa>کارشناس ارشد بهداشت محیط، مرکز تحقیقات ارتقاء سلامت، دانشکده بهداشت، دانشگاه علوم پزشکی زاهدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Saeideh</first_name>
	<middle_name></middle_name>
	<last_name>Keikhaei</last_name>
	<suffix></suffix>
	<first_name_fa>سعیده</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کیخایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460086531</code>
	<orcid>100319475328460086531</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc in Chemical Engineering, School of Chemical Engineering, Sistan and Baluchestan, Zahedan, Iran</affiliation>
	<affiliation_fa>کارشناس ارشد مهندسی شیمی، دانشکده مهندسی شیمی، دانشگاه سیستان و بلوچستان، زاهدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Amir Hossein</first_name>
	<middle_name></middle_name>
	<last_name>Mahvi</last_name>
	<suffix></suffix>
	<first_name_fa>امیرحسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460086532</code>
	<orcid>100319475328460086532</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Environmental Health, Faculty of Health, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>استادیار، ﮔﺮوه ﺑﻬﺪاﺷﺖ ﻣﺤﻴﻂ، داﻧﺸﻜﺪه ﺑﻬﺪاﺷﺖ، داﻧﺸﮕﺎه ﻋﻠﻮم ﭘﺰﺷﻜﻲ ﺗﻬﺮان، ﺗﻬﺮان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
