<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>140</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی انکسار پرتوهای فراصوت در هایفوتراپی و بهینه سازی عمق کانونی مبدل فراصوت جهت افزایش دقت درمان</title_fa>
	<title>Evaluation of Ultrasonic Beam Refraction in HIFU Therapy and Focal Depth Optimization in Ultrasonic Transducer to Increase the Treatment Accuracy</title>
	<subject_fa>فیزیک پزشکی</subject_fa>
	<subject>Medical physics</subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;سابقه و هدف: امروزه امواج متمرکز فراصوت با شدت بالا (&lt;span dir=&quot;LTR&quot;&gt;HIFU&lt;/span&gt;) به عنوان تابش غیریونیزان جهت درمان سرطان استفاده می&#8204;شود. پرتوهای فراصوت هنگام عبور از مرز دو محیط دچار انحراف می&#8204;شوند که باعث کاهش تمرکز باریکه پرتو در داخل تومور می&#8204;شود. هم&#8204;چنین ممکن است منجر به ایجاد آسیب در بافت&#8204;های سالم شوند. هدف از این مطالعه بررسی تغییرات عمق کانونی مبدل ناشی از انحراف پرتوهای فراصوت بوده است.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;مواد و روش&#8204;ها: در این مطالعه تجربی ابتدا میزان جابجایی ناشی از اختلاف سرعت در دو بافت مشخص برای یک المنت ترانسدیوسر محاسبه شد. سپس به تمامی المنت&#8204;های ترانسدیوسر تعمیم داده شد و میزان جابه&#8204;جایی کلی محاسبه گردید. پیاده&#8204;سازی الگوریتم&#8204;های طراحی شده در نرم&#8204;افزار متلب انجام شد. هم چنین برای انجام شبیه&#8204;سازی هایفوتراپی از شبیه&#8204;ساز &lt;span dir=&quot;LTR&quot;&gt;HIFU&lt;/span&gt; سازمان غذا و داروی آمریکا استفاده گردید.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;یافته&#8204;ها: نتایج نشان داد که انحراف پرتوها ناشی از اختلاف سرعت در دو بافت منجر به تغییر در نقطه کانونی می&#8204;شود. بنابراینالگوریتمی جهت کنترل عمق کانونی ارائه شد که روی 4 مدل با دولایه بافت تست شد. نتایج نشان دادندکه در صورت استفاده از الگوریتم، بخش اعظم جابه&#8204;جایی نقطه کانونی اصلاح می&#8204;شود. هم&#8204;چنین مشخص شد که بخشی از این جابه&#8204;جایی ناشی از جذب باریکه در بافت&#8204;ها می&#8204;باشد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;استنتاج: عدم کنترل جابه&#8204;جایی نقطه کانونی می&#8204;تواند باعث آسیب به بافت سالم شود. بنابراین بااستفاده از الگوریتم&#8204;های محاسباتی می&#8204;توان به طور چشم گیری جابجایی نقطه کانونی را در درمان به روش &lt;span dir=&quot;LTR&quot;&gt;HIFU&lt;/span&gt; اصلاح کرد. این منجر به افزایش ایمنی و داشتن کنترل مناسب در درمان به روش &lt;span dir=&quot;LTR&quot;&gt;HIFU&lt;/span&gt; می&#8204;شود.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and purpose:&lt;/strong&gt; Nowadays High-intensity focused ultrasound (HIFU) as non-ionizing radiation is used for cancer treatment. Ultrasound beams when crossing the border of two environments are refracted causing decrease in the beam focusing within a tumor. Also, it may induce damage to normal tissues. In this study, we evaluated the focal depth shift induced by ultrasonic beam refraction.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Materials and methods:&lt;/strong&gt; At first, the level of shift caused by the difference in two specific tissues were calculated for one element of transducer. Then it extended to all of the transducer elements and total shift was calculated. Designed algorithms were implemented in MATLAB. Also, HIFU simulator was used according to the US Food and Drug Administration (FDA) regulations to simulate HIFU therapy.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; The results showed that beam refraction caused by different velocity shifted the focal point. Therefore, an algorithm was proposed for controlling the focal depth and was tested on four models with two layers of tissue. Results showed that using the proposed algorithm corrected much of the focal point shift. Also, it was noted that a part of this shift was caused by absorption of the beam in tissues.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Not controlling the focal point shift can induce damage to normal tissues. Therefore, using computational algorithms significantly corrected the focal point shift and lead to increasing safety and having adequate control in HIFU therapy.&lt;/p&gt;
</abstract>
	<keyword_fa>اصلاح جابه‌جایی, عمق کانونی, شبیه‌ساز, هایفوتراپی</keyword_fa>
	<keyword>refraction correction, focal depth, simulator, HIFU therapy</keyword>
	<start_page>137</start_page>
	<end_page>147</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-3397-75&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammad</first_name>
	<middle_name></middle_name>
	<last_name>Rezaei</last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رضائی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460084717</code>
	<orcid>100319475328460084717</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Sleep Disorders Research Center, Kermanshah University of Medical Sciences (KUMS), Kermanshah, Iran</affiliation>
	<affiliation_fa>مرکز تحقیقات اختلالات خواب، دانشگاه علوم پزشکی کرمانشاه، کرمانشاه، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Karim</first_name>
	<middle_name></middle_name>
	<last_name>Khoshgard</last_name>
	<suffix></suffix>
	<first_name_fa>کریم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خوش گرد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>khoshgardk@gmail.com</email>
	<code>100319475328460084718</code>
	<orcid>100319475328460084718</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Assistant Professor, Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran</affiliation>
	<affiliation_fa>ستادیار، گروه فیزیک پزشکی و مهندسی پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی کرمانشاه، کرمانشاه، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Abbas</first_name>
	<middle_name></middle_name>
	<last_name>Haghparast</last_name>
	<suffix></suffix>
	<first_name_fa>عباس</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حق پرست</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460084719</code>
	<orcid>100319475328460084719</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran</affiliation>
	<affiliation_fa>ستادیار، گروه فیزیک پزشکی و مهندسی پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی کرمانشاه، کرمانشاه، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
