<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>140</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی آلودگی فوتونی اپلیکاتور Beam Shaper با استفاده از شبیه سازی مونت ‌کارلو</title_fa>
	<title>Evaluating the Photon Contamination of Beam Shaper Applicator Using Monte Carlo Simulation</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>گزارش کوتاه</content_type_fa>
	<content_type>Brief Report</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;سابقه و هدف: &lt;span dir=&quot;LTR&quot;&gt;Beam Shaper&lt;/span&gt; نوعی اپلیکاتور مورد استفاده در رادیوتراپی حین عمل توسط الکترون است. هدف از این مطالعه بررسی کمی میزان آلودگی فوتونی ناشی از این اپلیکاتور با استفاده از شبیه&#8204;سازی مونت&#8204;کارلو می&amp;shy;باشد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;مواد و روش&#8204;ها: در این مطالعه تجربی ابتدا سر شتاب دهنده &lt;span dir=&quot;LTR&quot;&gt;LIAC&lt;/span&gt; به همراه اپلیکاتور &lt;span dir=&quot;LTR&quot;&gt;Beam Shaper&lt;/span&gt; توسط کد مونت کارلوی &lt;span dir=&quot;LTR&quot;&gt;MCNPX&lt;/span&gt; شبیه&#8204;سازی گردید و سپس اعتبار مدل شبیه&#8204;سازی&#8204;شده از طریق مقایسه منحنی&#8204;های درصد دوز عمقی حاصل از شبیه&#8204;سازی مونت کارلو و دوزیمتری عملی مورد ارزیابی قرار گرفت. در نهایت میزان آلودگی فوتونی در اندازه&#8204;های میدان و انرژی&#8204;های مختلف به &#8204;صورت کمی در سطح فانتوم آب مورد بررسی قرار گرفت.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;یافته&#8204;ها: نتایج حاصل از این کار نشان داد که میزان آلودگی فوتونی ناشی از اپلیکاتور &lt;span dir=&quot;LTR&quot;&gt;beam shaper&lt;/span&gt; با افزایش ابعاد میدان به&#8204;طور قابل&#8204;توجهی کاهش می&#8204;یابد. به علاوه میزان آلودگی فوتونی با افزایش انرژی بیش&#8204;تر می&#8204;شود.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;استنتاج: افزایش میزان آلودگی فوتونی در سطح فانتوم با کاهش ابعاد میدان و افزایش انرژی را می&#8204;توان به افزایش احتمال برهم کنش الکترون با تیغه&#8204;های فلزی اپلیکاتور و تولید تابش ترمزی در انرژی&#8204;های بالاتر نسبت داد. استفاده از اپلیکاتور &lt;span dir=&quot;LTR&quot;&gt;beam shaper&lt;/span&gt; به دلیل ایجاد آلودگی فوتونی باعث افزایش میزان دوز رسیده به سطح خواهد شد.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and purpose:&lt;/strong&gt; Beam shaper is a type of applicator used in conjunction with the intraoperative electron radiotherapy. This study aimed at quantitative evaluation of the photon contamination of this applicator using Monte Carlo simulation.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Materials and methods:&lt;/strong&gt; In this experimental study, at first the head of LIAC accelerator was simulated along with the beam shaper applicator using MCNPX Monte Carlo code. Validity of the simulated model was evaluated by comparing the percentage depth dose curves obtained by Monte Carlo simulation and practical dosimetry. Finally, the photon contamination at different clinical field sizes and electron energies was quantitatively determined.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; The results showed that by increase in field size, the photon contamination of the beam shaper applicator was considerably decreased. Furthermore, increment of electron energy could increase the photon contamination.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Increasing the photon contamination at the phantom surface by increment of electron energy and decrement of field size can be attributed to increasing the probability of electron interaction with the steel blades of the beam shaper and production of bremsstrahlung radiation at higher energies. Due to the photon contamination, employing the beam shaper applicator can increase the surface dose.&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>رادیوتراپی حین عمل, آلودگی فوتونی, اپلیکاتور Beam Shaper, شبیه‌سازی مونت کارلو</keyword_fa>
	<keyword> intraoperative radiotherapy, photon contamination, beam shaper applicator, Monte Carlo Simulation</keyword>
	<start_page>212</start_page>
	<end_page>217</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-5029-323&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Nematollah </first_name>
	<middle_name></middle_name>
	<last_name>Heidarloo</last_name>
	<suffix></suffix>
	<first_name_fa>نعمت الله </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حیدرلو</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460066144</code>
	<orcid>100319475328460066144</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc in Radiation Medicine, Faculty of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran</affiliation>
	<affiliation_fa>کارشناسی ارشد پرتوپزشکی، دانشکده مهندسی هسته ای، دانشگاه شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hamid Reza </first_name>
	<middle_name></middle_name>
	<last_name>Baghani</last_name>
	<suffix></suffix>
	<first_name_fa>حمیدرضا </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>باغانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hamidreza.baghani@gmail.com</email>
	<code>100319475328460066145</code>
	<orcid>100319475328460066145</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Assistant Professor, Department of Radiation Medicine, Faculty of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran </affiliation>
	<affiliation_fa>استادیار، گروه پرتوپزشکی، دانشکده مهندسی هسته ای، دانشگاه شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mahmoud Reza </first_name>
	<middle_name></middle_name>
	<last_name>Aghamiri</last_name>
	<suffix></suffix>
	<first_name_fa> محمودرضا </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آقامیری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460066146</code>
	<orcid>100319475328460066146</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Professor, Department of Radiation Medicine, Faculty of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran</affiliation>
	<affiliation_fa>استاد، گروه پرتوپزشکی، دانشکده مهندسی هسته ای، دانشگاه شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name> Rabi </first_name>
	<middle_name></middle_name>
	<last_name>Mahdavi</last_name>
	<suffix></suffix>
	<first_name_fa> ربیع </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مهدوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460066147</code>
	<orcid>100319475328460066147</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Department of Medical Physics, Faculty of Medicine, Iran University of Medical Science, Tehran, Iran</affiliation>
	<affiliation_fa> دانشیار، گروه فیزیک پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
