<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>143</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>حذف مترونیدازول با استفاده از پرسولفات فعال شده با ازن  در حضور امواج فراصوت در محیط های آبی</title_fa>
	<title>Removal of Metronidazole Using Ozone Activated Persulfate from Aqua Solutions in Presence of Ultrasound </title>
	<subject_fa>بهداشت محیط زیست</subject_fa>
	<subject>Environmental Health</subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;سابقه و هدف: مترونیدازول از جمله فراورده&#8204;های داروئی است که به دلیل گستردگی مصرف و مقاومت در برابر تجزیه بیولوژیکی از آلاینده&#8204;های مهم در محیط به شمار می&#8204;رود. لذا این مطالعه به منظور بررسی امکان حذف این ماده آلی با استفاده از فرایند فعال&#8204;سازی پرسولفات با استفاده از ازن در حضور امواج فراصوت مورد بررسی قرار گرفته است.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;مواد و روش&#8204;ها: این مطالعه در مقیاس آزمایشگاهی و در سیستم ناپیوسته با استفاده از راکتور حاوی مولد امواج فراصوت در فرکانس 40 کیلوهرتز و سیستم تولید ازن به میزان 5/0 گرم در لیتر انجام شد. تاثیر پارامترهای بهره برداری نظیر &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; محلول (11-3)، غلظت پرسولفات (100 تا 1000 میلی گرم در لیتر)، غلظت اولیه مترونیدازول (5 تا 30 میلی&#8204;گرم در لیتر)، تغییرات شدت یونی (13/0 تا 03/1 گرم در لیتر) و تاثیر ترت بوتانل در عملکرد فرایند مورد بررسی قرار گرفت. هم&#8204;چنین میزان معدنی&#8204;سازی از طریق اندازه گیری &lt;span dir=&quot;LTR&quot;&gt;COD&lt;/span&gt; تعیین شد. غلظت مترونیدازول با استفاده از دستگاه اسپکتروفتومتر در طول موج 320 نانومتر اندازه&#8204;گیری شد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;یافته&#8204;ها: نتایج حاصل از این مطالعه نشان داد که با افزایش &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; محلول از 3 تا 11 کارائی، حذف ماده آلی کاهش یافت، به نحوی که بیش&#8204;ترین حذف مترونیدازول در &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; های 3 و 5 به ترتیب برابر با 92 و 90 درصد در زمان تماس 60 دقیقه به دست آمد. کارایی حذف مترونیدازول به غلظت اولیه پرسولفات بستگی داشته و بیش&#8204;ترین حذف ماده آلی در غلظت&#8204;های اولیه 500 و 750 میلی&#8204;گرم بر لیتر به ترتیب به میزان 7/94 و 95 درصد حاصل و در مقادیر بیش از آن راندمان حذف کاهش یافت. نتایج بیانگر آن بود که با افزایش غلظت اولیه مترونیدازول، میزان حذف کاهش یافت. هم&#8204;چنین تغییرات شدت یونی بر عملکرد فرایند، تاثیر نداشت. بر اساس دیگر نتایج این مطالعه، بیش&#8204;ترین رادیکال فعال در این فرایند، رادیکال پرسولفات بود. میزان حذف &lt;span dir=&quot;LTR&quot;&gt;COD&lt;/span&gt; در شرایط بهینه بهره&#8204;برداری، 56 درصد بود.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;استنتاج: استفاده از فرایند فعال&#8204;سازی پرسولفات با استفاده از ازن در حضور امواج فراصوت به میزان قابل توجهی می&#8204;تواند مترونیدازول را حذف و به عنوان یک روش کارآمد به تنهائی یا به عنوان پیش تصفیه مورد استفاده قرار گیرد.&lt;/p&gt;
&lt;p dir=&quot;RTL&quot;&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and purpose:&lt;/strong&gt; Metronidazole is a serious environmental pollutant due to high consumption and persistence in biological degradation. This study aimed at removal of metronidazole using ozone (O&lt;sub&gt;3&lt;/sub&gt;) activated persulfate (PS) in presence of ultrasound (US).&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Materials and methods:&lt;/strong&gt; A laboratory scale study was carried out in batch reactor using US irradiation and O&lt;sub&gt;3&lt;/sub&gt; generator apparatuses. The effects of operating parameters such as pH of the solution, different initial concentrations of persulfate, initial metronidazole concentration, different ion strength, and radical scavenger were evaluated. Metronidazole concentration was determined using DR-5000 Spectrophotometer in 320 nm wavelength.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; The results showed that removal of metronidazole decreased by increasing the pH of solution from 3 to 11. The removal rate of metronidazole was dependent on initial PS dosages and the highest rate of removal was found in 500 mg/l (94.7%), but in higher concentrations the removal rate decreased. Also, the metronidazole removal rate decreased by increase in initial concentration of metronidazole. The COD removal rate in optimum condition was 56%.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Activation of PS by US/O&lt;sub&gt;3&lt;/sub&gt; process could serve as a novel treatment for removal of metronidazole in aqueous solution.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;</abstract>
	<keyword_fa>امواج فراصوت, ازن, فعال سازی پرسولفات, مترونیدازول</keyword_fa>
	<keyword>ultrasound, ozonation, persulfate activation, metronidazole</keyword>
	<start_page>160</start_page>
	<end_page>173</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-5029-373&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Abdolmotalleb</first_name>
	<middle_name></middle_name>
	<last_name> Seidmohammadi</last_name>
	<suffix></suffix>
	<first_name_fa>عبدالمطلب</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صیدمحمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460085883</code>
	<orcid>100319475328460085883</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Social Determinants of Health Research Center, Department of Environmental Health Engineering, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran</affiliation>
	<affiliation_fa>دانشیار، مرکز تحقیقات عوامل اجتماعی موثر بر سلامت، گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Ghorban </first_name>
	<middle_name></middle_name>
	<last_name>Asgari</last_name>
	<suffix></suffix>
	<first_name_fa>قربان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عسگری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460085884</code>
	<orcid>100319475328460085884</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Social Determinants of Health Research Center, Department of Environmental Health Engineering, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran</affiliation>
	<affiliation_fa>دانشیار، مرکز تحقیقات عوامل اجتماعی موثر بر سلامت، گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Leyla </first_name>
	<middle_name></middle_name>
	<last_name>Torabi</last_name>
	<suffix></suffix>
	<first_name_fa>لیلا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ترابی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>torabiliela@yahoo.com</email>
	<code>100319475328460085885</code>
	<orcid>100319475328460085885</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>MSc in Environmental Health Engineering, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran</affiliation>
	<affiliation_fa>کارشناسی ارشد مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
