<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>143</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی تاثیر اندازه میدان فوتونی بر بیناب نوترون آلاینده در شتابدهنده خطی Elekta SL75/25 در انرژی MV18 به روش مونت کارلو</title_fa>
	<title>A Monte Carlo Investigation on the Effect of Field Size on Neutron Spectrum in Elekta SL 75/25 Linac on 18 MV</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>گزارش کوتاه</content_type_fa>
	<content_type>Brief Report</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;سابقه و هدف: فوتون&#8204;های با انرژی بیش از 10-8 مگا ولت در شتابدهنده خطی در طول مسیر خود از هدف تا سطح پوست بیمار با اجزای مختلفی برخورد می&#8204;کنند که می&#8204;تواند منجر به تولید آلودگی نوترونی گردد. با توجه به تضعیف نوترون به دلیل بسته شدن زاویه فک&#8204;های کولیماتور در اندازه میدان&#8204;های کوچک تر، اندازه میدان می&#8204;تواند یک عامل موثر در تغییر بیناب نوترون باشد. از آن&#8204;جایی که اندازه&#8204;گیری مستقیم شار و بیناب نوترون در داخل اتاق درمان نیاز به اندازه&#8204;گیری&#8204;های پیچیده دارد، مونت کارلو یک روش جایگزین برای تعیین درست بیناب نوترون است.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;مواد و روش&#8204;ها: هندسه سر شتابدهنده خطی &lt;span dir=&quot;LTR&quot;&gt;Elekta SL75/25&lt;/span&gt; &amp;nbsp;در کد شبیه سازی &lt;span dir=&quot;LTR&quot;&gt;FLUKA&lt;/span&gt; طراحی شد و مورد اعتبار سنجی قرار گرفت. بیناب نوترون تولید شده در این شتابدهنده، در مرکز چهار اندازه میدان 20&amp;times;20، 15&amp;times;15، 10&amp;times;10 و 5 &amp;times;5 سانتی&#8204;متر مربع تعیین شد. جهت آنالیز داده&#8204;ها از آزمون آماری من ویتنی استفاده شد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;یافته&#8204;ها: در حالت با فیلتر پهن کننده، فقط از اندازه میدان 5 &amp;times;5 تا 15&amp;times;15 سانتی&#8204;متر مربع و 5 &amp;times;5 تا 20&amp;times;20 سانتی&#8204;متر مربع، اختلاف در بیناب نوترون معنی&#8204;دار است (05/0&lt;span dir=&quot;LTR&quot;&gt;p&lt;&lt;/span&gt;).&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;استنتاج: نتایج بیناب نوترون توسط کد شبیه سازی &lt;span dir=&quot;LTR&quot;&gt;Fluka&lt;/span&gt; با نتایج مربوط به دزیمتری عملی سایر محققین تطابق خوبی داشت؛ بنابراین بررسی شار نوترونی در رادیوتراپی به وسیله شبیه&#8204;سازی می&#8204;تواند راهکاری مناسب در جهت بهبود درمان بیمار و مباحث حفاظتی باشد. هم&#8204;چنین با توجه به افزایش دز نوترون با افزایش اندازه میدان، می توان بیان کرد اندازه میدان بر بروز آثار ثانویه درمان تأثیرگذار است.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and purpose:&lt;/strong&gt; High-energy photon beams above 8-10 MV used in external radiation therapy produce neutron in dealing with the linear accelerator components and other parts in radiation field. T&lt;em&gt;he weakening&lt;/em&gt; &lt;em&gt;of neutrons&lt;/em&gt; &lt;em&gt;due to the closing&lt;/em&gt; &lt;em&gt;jaws&lt;/em&gt; &lt;em&gt;collimator&lt;/em&gt; &lt;em&gt;angle,&lt;/em&gt;&amp;nbsp;&lt;em&gt;in smaller&lt;/em&gt; &lt;em&gt;field sizes&lt;/em&gt; &lt;em&gt;can also be a&lt;/em&gt; &lt;em&gt;contributing factor&lt;/em&gt; &lt;em&gt;in changing the&lt;/em&gt; &lt;em&gt;neutron&lt;/em&gt; &lt;em&gt;spectrum. &lt;/em&gt;Since a direct measurement of the neutron flux and spectrum&amp;nbsp;require complex measurements in treatment room, the Monte Carlo is an alternative method for determining the true environmental neutron spectrum.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Materials and methods:&lt;/strong&gt; Geometry of linear accelerator Elekta SL75/25 was designed in FLUKA simulation code and its validation was tested. Spectrum of neutrons produced in the accelerator was determined in the center of four field sizes of 20 &amp;times; 20, &amp;nbsp;&amp;nbsp;15 &amp;times; 15, 10 &amp;times; 10, and 5 &amp;times; 5 cm&lt;sup&gt;2&lt;/sup&gt;. Data analysis was done applying Mann-Whitney test.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; In the condition with flattening filter, significant differences was found in the neutron spectrum only in 5 &amp;times; 5 to 15 &amp;times; 15 cm&lt;sup&gt;2&lt;/sup&gt; and 5 &amp;times; 5 to 20 &amp;times; 20 cm&lt;sup&gt;2&lt;/sup&gt; field sizes (P&lt;0.05).&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Our results of the neutron spectrum using FLUKA simulation code are in a good conformity with the results of practical dosimetry of other researchers; therefore, checking the neutron flux in radiotherapy by simulation can be an appropriate solution to improve patient treatment and protection issues. Since neutron dose increases with an increase in field size, so, we can conclude that field size influences secondary effects of treatment.&lt;/p&gt;
</abstract>
	<keyword_fa>شتابدهنده خطی پزشکی, اندازه میدان, آلودگی نوترون, مونت کارلو</keyword_fa>
	<keyword>linear accelerator, neutron contamination, field size, Monte Carlo</keyword>
	<start_page>257</start_page>
	<end_page>262</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-5029-379&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Soroush </first_name>
	<middle_name></middle_name>
	<last_name>Sistani</last_name>
	<suffix></suffix>
	<first_name_fa>سروش</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سیستانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460085843</code>
	<orcid>100319475328460085843</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>MSc Student in Medical Physics, Student Research Committee, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran</affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد فیزیک پزشکی، کمیته تحقیقات دانشجویی، دانشکده پزشکی، دانشگاه علوم پزشکی سمنان، سمنان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Javad </first_name>
	<middle_name></middle_name>
	<last_name>Safari</last_name>
	<suffix></suffix>
	<first_name_fa>محمد جواد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صفری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460085844</code>
	<orcid>100319475328460085844</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>PhD Student in Phyisc, Amirkabir University of Technology, Tehran, Iran</affiliation>
	<affiliation_fa>دانشجوی دکتری فیزیک، دانشگاه صنعتی امیرکبیر، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Payman </first_name>
	<middle_name></middle_name>
	<last_name>Hejazi</last_name>
	<suffix></suffix>
	<first_name_fa>پیمان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حجازی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hejazip@semums.ac.ir</email>
	<code>100319475328460085845</code>
	<orcid>100319475328460085845</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Assistant Professor, Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran</affiliation>
	<affiliation_fa>استادیار، گروه فیزیک پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی سمنان، سمنان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
