<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>144</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی میزان آگاهی پرتوکاران، کارورزان پزشکی، دستیاران و دانشجویان رادیولوژی از مقدار دز دریافتی در روش های مختلف تصویربرداری</title_fa>
	<title>Knowledge of Medical Interns and Radiology Residents, Students, and Staff about the Radiation Dose Received by Patients in Different Imaging Methods</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;سابقه و هدف: حفاظت بیمار در مقابل خطرات پرتوهای یونیزان مورد استفاده برای مقاصد تشخیصی پزشکی مستلزم داشتن دانش کافی و آگاهی از مقدار، منابع و خطرات پرتوها می&#8204;باشد. هدف از این مطالعه بررسی میزان آگاهی پرتوکاران، کارورزان پزشکی، دستیاران و دانشجویان رادیولوژی دانشگاه علوم پزشکی کاشان از مقدار دز دریافتی در روش های مختلف تصویربرداری بوده است.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;مواد و روش&#8204;ها: مطالعه حاضر یک مطالعه کاربردی از نوع توصیفی-مقطعی بود. جامعه پژوهش 163 نفر از دستیاران، کارورزان پزشکی و دانشجویان سال آخر کارشناسی رادیولوژی و پرتوکاران شاغل در بیمارستان&#8204;های تابعه دانشگاه علوم پزشکی کاشان در سال 1394 بود. یک پرسش نامه محقق ساخته تهیه و در اختیار شرکت&#8204;کنندگان قرار گرفت. میانگین درصد پاسخ صحیح به سوالات در گروه&#8204;های شرکت&#8204;کننده با استفاده از نرم&#8204;افزار 16 &lt;span dir=&quot;LTR&quot;&gt;SPSS&lt;/span&gt; تعیین گردید. میانگین 75درصد به بالا به صورت آگاهی خیلی خوب، 50 تا 75 درصد آگاهی خوب، 25تا50 درصد آگاهی متوسط و کم&#8204;تر از 25 درصد آگاهی ضعیف در نظر گرفته شد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;یافته&#8204;ها: به طور کلی آگاهی نسبت به دز دریافتی در گروه پرتوکاران (45/2&amp;plusmn;9/57 درصد) و دانشجویان رادیولوژی (65/2&amp;plusmn;4/52 درصد) خوب درحالی که در کارورزان پزشکی (65/1&amp;plusmn;35/35 درصد) و دستیاران (6&amp;plusmn;35/41 درصد) متوسط بود.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;استنتاج: نتایج این مطالعه نشان می&#8204;دهد که آگاهی پرتوکاران و دانشجویان رادیولوژی نسبت به مقدار دز دریافتی در روش&#8204;های مختلف تصویربرداری خوب است درحالی که درکارورزان پزشکی و دستیاران تجدید نظر در سرفصل&#8204;های درسی با تاکید بیش&#8204;تر در مباحث حفاظت پرتویی ضروری به نظر می&#8204;رسد.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and purpose:&lt;/strong&gt; Knowledge&amp;nbsp;on the&amp;nbsp;risks of radiation during diagnostic imaging is necessary to protect patients against the hazards of ionizing radiation. The aim of this study was to investigate the level of knowledge of interns, radiology residents, radiology students, and staff about radiation doses received by patients in radiological examinations.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Materials and methods:&lt;/strong&gt; During a cross-sectional study, 163 individuals (interns, radiology residents, students, and staff in Kashan University of Medical Sciences) were asked to identify the average dose of radiation received by patients. A researcher-made questionnaire was administered. Average of correct answers in the groups was analyzed using the SPSS 16 software. The scores above 75%, 75-50%, 50-25%, and below 25% were considered as very good, good, moderate, and poor levels of knowledge, respectively.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; The mean scores for the level of knowledge about the dose received by patients were 57.9&amp;plusmn;2.45% and 52.4&amp;plusmn;2.65% in the staff and radiology students, while it was 35.35&amp;plusmn;-1.65% and 41.35&amp;plusmn;6% in interns and residents, respectively.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; In this study most of the radiology staff and students had good levels of knowledge about the radiation dose received by patients during diagnostic radiological methods. Therefore, revising curricula with more emphasis on radiation protection is recommended for medical interns and residents.&lt;/p&gt;
</abstract>
	<keyword_fa>آگاهی, دز دریافتی, رادیولوژی, پرتوکاران</keyword_fa>
	<keyword>knowledge, radiation, received dose, radiology staff</keyword>
	<start_page>230</start_page>
	<end_page>239</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-7282-27&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mahboubeh </first_name>
	<middle_name></middle_name>
	<last_name>Masoumbeigi</last_name>
	<suffix></suffix>
	<first_name_fa>محبوبه </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>معصوم بیگی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460071428</code>
	<orcid>100319475328460071428</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Lecturer, Department of Radiology and Medical Physics, Faculty of Paramedicine, Kashan University of Medical  Sciences, Kashan, Iran</affiliation>
	<affiliation_fa>مربی، گروه فیزیک پزشکی و رادیولوژی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی کاشان، کاشان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mehran </first_name>
	<middle_name></middle_name>
	<last_name>Mohseni</last_name>
	<suffix></suffix>
	<first_name_fa>مهران </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محسنی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460071429</code>
	<orcid>100319475328460071429</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Radiology and Medical Physics, Faculty of Paramedicine, Kashan University of Medical  Sciences, Kashan, Iran</affiliation>
	<affiliation_fa>استادیار، گروه فیزیک پزشکی و رادیولوژی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی کاشان، کاشان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hossein </first_name>
	<middle_name></middle_name>
	<last_name>Akbari</last_name>
	<suffix></suffix>
	<first_name_fa>حسین </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اکبری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460071430</code>
	<orcid>100319475328460071430</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Biostatistics and Public Health, Faculty of Health, Kashan University of Medical Sciences, Kashan, Iran</affiliation>
	<affiliation_fa>استادیار، گروه آمار زیستی و اپیدمیولوژی، دانشکده بهداشت، دانشگاه علوم پزشکی کاشان، کاشان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Akbar</first_name>
	<middle_name></middle_name>
	<last_name> Ali asgharzadeh</last_name>
	<suffix></suffix>
	<first_name_fa>اکبر </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علی اصغرزاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email> kums.ac.ir@ aliasgharzadeh_a</email>
	<code>100319475328460071431</code>
	<orcid>100319475328460071431</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Associate Professor, Department of Radiology and Medical Physics, Faculty of Paramedicine, Kashan University of Medical  Sciences, Kashan, Iran</affiliation>
	<affiliation_fa>دانشیار، گروه فیزیک پزشکی و رادیولوژی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی کاشان، کاشان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
