<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>144</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارزیابی اثر ناهمگنی هوا در محاسبات دوز  براکی تراپی HDR نای توسط فیلم EDR2</title_fa>
	<title>Evaluating the Effect of Air Inhomogeneity on Dose Calculations of Trachea HDR Brachytherapy Using EDR2 Film</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>گزارش کوتاه</content_type_fa>
	<content_type>Brief Report</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;سابقه و هدف: محاسبات دوز در سیستم&#8204;های طراحی درمان براکی تراپی &lt;span dir=&quot;LTR&quot;&gt;HDR&lt;/span&gt; نای عمدتاً بر مبنای پروتوکل &lt;span dir=&quot;LTR&quot;&gt;TG-43&lt;/span&gt; انجام می&#8204;گیرد که در این پروتوکل، تمام مواد از جمله هوای درون نای، معادل آب در نظر گرفته می&#8204;شود. هدف از این پژوهش، بررسی اثر هوا در محاسبات دوز براکی تراپی &lt;span dir=&quot;LTR&quot;&gt;HDR&lt;/span&gt; نای در سیستم طراحی درمان &lt;span dir=&quot;LTR&quot;&gt;Flexiplan&lt;/span&gt; می&#8204;باشد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;مواد و روش&#8204;ها: برای ارزیابی اثرات ناشی از ناهمگنی هوا از یک فانتوم استوانه&#8204;ای پلکسی گلاس معادل گردن استفاده گردید. برای اندازه&#8204;گیری دوز فیلم &lt;span dir=&quot;LTR&quot;&gt;EDR2&lt;/span&gt; به کار گرفته شد. طراحی درمان و پرتودهی نیز به ترتیب توسط نرم افزار &lt;span dir=&quot;LTR&quot;&gt;Flexiplan&lt;/span&gt; و سیستم براکی تراپی &lt;span dir=&quot;LTR&quot;&gt;Flexitron&lt;/span&gt; انجام گرفت.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;یافته&#8204;ها: نتایج نشان داد که معادل آب در نظر گرفته شدن هوای داخل نای می&#8204;تواند دوز جذب شده را به اندازه 12 درصد افزایش دهد که منجر به اضافه دوزگیری بیمار می&#8204;گردد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;استنتاج: با توجه به نتایج می&#8204;توان گفت که اختلاف معنی&#8204;داری میان نتایج دوزیمتری در دو حالت مورد مطالعه وجود دارد. بنابراین معادل آب در نظر گرفته شدن هوا اثر قابل توجهی در محاسبات دوز براکی تراپی &lt;span dir=&quot;LTR&quot;&gt;HDR&lt;/span&gt; نای و صحت طرح درمان انجام شده دارد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Background and purpose:&lt;/strong&gt; Dose calculations in trachea HDR brachytherapy treatment planning systems are greatly based on TG-43 protocol in which, all materials including air inside trachea are treated the same as water. The aim of this study was to survey the effect of air on dose calculations of Flexiplan treatment planning system in trachea HDR brachytherapy.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Materials and methods:&lt;/strong&gt; To evaluate the effect of air inhomogeneity, a neck-equivalent plexiglass cylindrical phantom was used. Dose measurement was carried out by EDR2 film. Treatment planning and irradiation were performed using Flexiplan software and Flexitron brachytherapy system, respectively.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; The results showed that considering the air inside trachea as water increases the absorbed dose by 12% which can lead to increment of patient dose.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; A significant difference was seen between dosimetry results in the two conditions. Therefore, taking the air similar to water has a considerable effect on dose calculations of trachea HDR brachytherapy and accuracy of treatment plan performed.&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>براکی تراپی HDR نای, ناهمگنی هوا, نرم‌افزار طراحی درمان Flexiplan, فیلم EDR2  مقدمه</keyword_fa>
	<keyword>trachea HDR brachytherapy, air inhomogeneity, Flexiplan treatment planning software, EDR2 film</keyword>
	<start_page>346</start_page>
	<end_page>351</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-7282-30&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohsen</first_name>
	<middle_name></middle_name>
	<last_name> Hosseini Daghigh</last_name>
	<suffix></suffix>
	<first_name_fa>محسن </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسینی دقیق</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460071499</code>
	<orcid>100319475328460071499</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>PhD Student in Radiation Medicine, School of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran</affiliation>
	<affiliation_fa>دانشجوی دوره دکتری پرتوپزشکی، دانشکده مهندسی هسته‌ای، دانشگاه شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hamid Reza </first_name>
	<middle_name></middle_name>
	<last_name>Baghani</last_name>
	<suffix></suffix>
	<first_name_fa>حمیدرضا </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>باغانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460071500</code>
	<orcid>100319475328460071500</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Assistant Professor, Department of Radiation Medicine, School of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran</affiliation>
	<affiliation_fa>استادیار، گروه پرتوپزشکی، دانشکده مهندسی هسته‌ای، دانشگاه شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name> Mahmoud Reza</first_name>
	<middle_name></middle_name>
	<last_name> Aghamiri</last_name>
	<suffix></suffix>
	<first_name_fa>محمودرضا </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آقامیری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>smr-aghamiri@sbu.ac.ir </email>
	<code>100319475328460071501</code>
	<orcid>100319475328460071501</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Professor, Department of Radiation Medicine, School of Nuclear Engineering, Shahid Beheshti University, Tehran, Iran</affiliation>
	<affiliation_fa>استاد، گروه پرتوپزشکی، دانشکده مهندسی هسته‌ای، دانشگاه شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name> Rabi </first_name>
	<middle_name></middle_name>
	<last_name>Mahdavi</last_name>
	<suffix></suffix>
	<first_name_fa>ربیع </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مهدوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460071502</code>
	<orcid>100319475328460071502</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Associate Professor, Department of Medical Physics, School of Medicine, Iran University of Medical Science, Tehran, Iran</affiliation>
	<affiliation_fa>دانشیار، گروه فیزیک پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
