<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>27</volume>
<number>147</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>اندازه‌گیری دوز ورودی سطح و دوز مؤثر بیماران در رادیولوژی قفسه سینه و شکم در همدان و مقایسه با استاندارد جهانی</title_fa>
	<title>Measuring the Entrance Surface Dose and Effective Dose for Chest and Abdomen X-ray Examinations in Hamedan, Iran and their Comparison with International Standards</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;سابقه و هدف&lt;strong&gt;:&lt;/strong&gt; با افزایش استفاده از پرتوهای ایکس در تشخیص پزشکی، آگاهی از میزان دوز دریافتی&lt;br clear=&quot;all&quot; &gt;
بیماران و مقایسه آن با سطح استاندارد جهانی ضروری است. هدف از این مطالعه، تخمین دوز ورودی سطح&lt;br clear=&quot;all&quot; &gt;
(&lt;span dir=&quot;LTR&quot;&gt;ESD&lt;/span&gt; :&lt;span dir=&quot;LTR&quot;&gt;Entrance Surface Dose&lt;/span&gt;) و دوز مؤثر (&lt;span dir=&quot;LTR&quot;&gt;Effective Dose: ED&lt;/span&gt;) بیماران در تصویربرداری (قفسه سینه و شکم) با سیستم&#8204;های رادیولوژی تشخیصی در شهر همدان بود. در مرحله بعدی، مقادیر اندازه&#8204;گیری&lt;span dir=&quot;LTR&quot;&gt;&amp;lrm;&lt;/span&gt;شده با نتایج گزارش&lt;span dir=&quot;LTR&quot;&gt;&amp;lrm;&lt;/span&gt;شده از دیگر شهرهای ایران و استاندارد &lt;span dir=&quot;LTR&quot;&gt;International Atomic Energy Agency&lt;/span&gt; (&lt;span dir=&quot;LTR&quot;&gt;IAEA&lt;/span&gt;) مقایسه گردید.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;مواد و روش&#8204;ها&lt;strong&gt;:&lt;/strong&gt; نمونه&#8204;های مورد مطالعه، از بین بیماران مراکز رادیولوژی شهر همدان انتخاب شدند. سه عدد &lt;em&gt;دوز&lt;/em&gt;یمتر ترمولومینسانس &lt;span dir=&quot;LTR&quot;&gt;TLD&lt;/span&gt; برای اندازه&#8204;گیری دوز هر بیمار استفاده گردید. اندازه&#8204;گیری&#8204;ها بر روی ده بیمار (برای هر اندام و دستگاه) انجام و اطلاعات بیمار، دستگاه و شرایط تابش&#8204;دهی ثبت شد. &lt;span dir=&quot;LTR&quot;&gt;ESD&lt;/span&gt; و &lt;span dir=&quot;LTR&quot;&gt;ED&lt;/span&gt; محاسبه و با مقادیر گزارش&#8204;شده از مطالعات دیگر و همچنین مقدار استاندارد &lt;span dir=&quot;LTR&quot;&gt;IAEA&lt;/span&gt; مقایسه گردید.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;یافته&#8204;ها&lt;strong&gt;:&lt;/strong&gt; نتایج &lt;span dir=&quot;LTR&quot;&gt;ESD&lt;/span&gt; نشان داد که تفاوت معناداری بین مدل&#8204;های مختلف دستگاه&#8204;های رادیولوژی وجود ندارد (05/0&lt;&lt;span dir=&quot;LTR&quot;&gt;P&lt;/span&gt;). در این مطالعه میانگین &lt;span dir=&quot;LTR&quot;&gt;ESD&lt;/span&gt; برای قفسه سینه و شکم، به&#8204;ترتیب 09/0 &amp;plusmn; 43/0 و &lt;span dir=&quot;LTR&quot;&gt;&amp;nbsp;mGy&lt;/span&gt; 19/0 &amp;plusmn; 51/2 و میانگین &lt;span dir=&quot;LTR&quot;&gt;ED&lt;/span&gt; محاسبه&#8204;شده برای قفسه سینه و شکم به&#8204;ترتیب 05/0 و &lt;span dir=&quot;LTR&quot;&gt;msv&lt;/span&gt; 33/0 بود.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;استنتاج&lt;strong&gt;:&lt;/strong&gt; مقدار &lt;span dir=&quot;LTR&quot;&gt;ESD&lt;/span&gt; محاسبه&#8204;شده برای قفسه سینه بالاتر و برای شکم کمتر از سطح &lt;span dir=&quot;LTR&quot;&gt;IAEA&lt;/span&gt; بود. میانگین &lt;span dir=&quot;LTR&quot;&gt;ED&lt;/span&gt; برای هر دو روش تصویربرداری از قفسه سینه و شکم، از سطح استاندارد &lt;span dir=&quot;LTR&quot;&gt;IAEA&lt;/span&gt; پایین&#8204;تر بود.&lt;/p&gt;
&lt;p dir=&quot;RTL&quot;&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and purpose:&lt;/strong&gt; By increasing use of X-ray in medical diagnosis, it is essential to gain awareness on the amount of absorbed dose in patients according to the world standard levels. The aim of this study was to estimate the entrance surface dose (ESD) and effective dose (ED) of the patients in imaging (chest and abdomen) with diagnostic radiology systems in Hamadan, Iran; and comparing the results with those reported from other cities of Iran and the safety standards proposed by International Atomic Energy Agency (IAEA).&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Materials and methods: &lt;/strong&gt;The participants included 10 patients attending Hamedan radiology centers. Three thermoluminescent dosimeters (TLD) were used to measure the dose of each patient. The measurements were performed for each organ and system and the information of patients, system, and exposure conditions was recorded. Then, the ESD and ED values were calculated and the results were compared with those reported by other studies and the IAEA standard levels.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results: &lt;/strong&gt;The ESD values showed no significant difference between various models of radiology systems (P&gt;0.05). The mean ESD values in current study for chest and abdomen X-ray were 0.43&amp;plusmn;0.09 and 2.51&amp;plusmn;0.19 mGy, repectively. The mean ED values for chest and abdomen radiology were 0.05 and 0.33 mSv, respectively.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; The ESD value calculated for chest X-ray was higher than that suggested by IAEA, but this value for abdomen was found to be lower than that accepted by IAEA. Moreover, the mean ED values for both chest and abdomen radiology examinations were lower than those proposed by the IAEA.&lt;/p&gt;
</abstract>
	<keyword_fa>رادیولوژی شکم, رادیولوژی قفسه سینه, دوز جذبی, دوز مؤثر, دوز ورودی سطحی پوست</keyword_fa>
	<keyword>abdomen radiology, absorbed dose, chest radiology, effective dose, entrance surface dose</keyword>
	<start_page>249</start_page>
	<end_page>258</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-4374-52&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Maryam </first_name>
	<middle_name></middle_name>
	<last_name>Pourkaveh</last_name>
	<suffix></suffix>
	<first_name_fa>مریم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پورکاوه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460083871</code>
	<orcid>100319475328460083871</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه رادیولوژی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Safoora </first_name>
	<middle_name></middle_name>
	<last_name>Nikzad</last_name>
	<suffix></suffix>
	<first_name_fa>صفورا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نیکزاد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>s.nikzad@umsha.ac.ir</email>
	<code>100319475328460083872</code>
	<orcid>100319475328460083872</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Naghi </first_name>
	<middle_name></middle_name>
	<last_name>Jabbari vesa</last_name>
	<suffix></suffix>
	<first_name_fa>نقی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جباری وصال</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460083873</code>
	<orcid>100319475328460083873</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشکده پزشکی، دانشگاه علوم پزشکی همدان، همدان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
