<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>27</volume>
<number>147</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تصفیه شیرابه محل دفن پسماند با استفاده از فرآیندهای ترکیبی انعقاد شیمیایی، ازن زنی و اکسیداسیون پیشرفته با آکسون فعال‌شده به‎وسیله پرتو فرابنفش </title_fa>
	<title>Landfill Leachate Treatment by Combined Processes of Chemical Coagulation, Ozonation, and Advanced Oxidation Using UV-activated Oxone</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;سابقه و هدف:در حال حاضر، تولیدشیرابه و مدیریت آن به&#8204; عنوان بزرگ&#8204;ترین مشکل زیست&#8204;محیطیمرتبطبا بهره&#8204;برداری از محل دفن پسماندشناخته می&lt;span dir=&quot;LTR&quot;&gt;&amp;lrm;&lt;/span&gt;شود. این مطالعه، با هدف ارزیابی کارایی فرآیندهای ترکیبی انعقاد شیمیایی و ازن زنی-اکسیداسیون پیشرفته،به &lt;span dir=&quot;LTR&quot;&gt;&amp;lrm;&lt;/span&gt;وسیله آکسون فعال&#8204;شده با پرتو فرابنفش در تصفیه شیرابه تولیدشده از محل دفن پسماندشهر زاهدان طراحی و اجرا شد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;موادو روش&#8204;ها: این مطالعه تجربی&amp;ndash;آزمایشگاهی، شامل مراحل انعقاد شیمیایی با استفاده از منعقدکننده پلی آلومینیوم کلراید، ازن زنی و اکسیداسیون شیمیایی به&lt;span dir=&quot;LTR&quot;&gt;&amp;lrm;&lt;/span&gt; وسیله پتاسیم پروکسی مونو سولفات (آکسون) بود. بدین منظور، اثر متغیرهای مهم بهره&#8204;برداری شامل:&lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; (8-3) و غلظت منعقد کننده پلی آلومینیوم کلراید (&lt;span dir=&quot;LTR&quot;&gt;mg/l&lt;/span&gt;250-50)`درفرآیندانعقادشیمیایی، مدت&#8204;زمان فرآیندازن زنی (20-5دقیقه) و&lt;span dir=&quot;LTR&quot;&gt;pH&amp;nbsp;&lt;/span&gt; محلول (10-2)،غلظت واکنش&#8204;گرآکسون (&lt;span dir=&quot;LTR&quot;&gt;mg/l&lt;/span&gt;750-150)،زمان تماس با آکسون (360-60 دقیقه)،درجه حرارت (45-20 درجه سانتی&#8204;گراد)و توان لامپ فرابنفش (8، 15 و &lt;span dir=&quot;LTR&quot;&gt;W&lt;/span&gt; 30) درفرآینداکسیداسیون با آکسون، برای تصفیه شیرابه پسماند بررسی شد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;یافته&#8204;ها: بازده کلی فرآینددرحذف شاخص&#8204;های کلیفرم کل، کلیفرم مدفوعی، کل فسفر، کل ازت، اکسیژن موردنیاز بیوشیمیایی و اکسیژن موردنیاز شیمیایی با مقادیر بهینه منعقدکننده پلی آلومینیوم کلراید (&lt;span dir=&quot;LTR&quot;&gt;mg/l&lt;/span&gt;250، &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; معادل 6 در مرحله انعقاد شیمیایی، مدت&#8204;زمان ازن زنی برابر 20 دقیقه و زمان واکنش معادل 180 دقیقه طی فرآیند اکسیداسیون با واکنش&#8204;گرآکسون، غلظت آکسون برابر&lt;span dir=&quot;LTR&quot;&gt;mg/l&lt;/span&gt; 750، &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; برابر 5، درجه حرارت 25 درجه سانتی&#8204;گراد و توان لامپ پرتو فرابنفش معادل &lt;span dir=&quot;LTR&quot;&gt;W&lt;/span&gt;8، به&lt;span dir=&quot;LTR&quot;&gt;&amp;lrm;&lt;/span&gt;ترتیب برابر 99، 99، 97، 100، 1/91 و 62/85 درصد به&#8204;دست آمد. همچنین، نسبت&lt;span dir=&quot;LTR&quot;&gt;BOD&lt;sub&gt;5&lt;/sub&gt;/COD&lt;/span&gt;از 42/0 در ابتدای فرآیند به 72/0 درصد پس از تکمیل فرآیندهای تصفیه افزایش یافت.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;استنتاج: نتایجبه&lt;span dir=&quot;LTR&quot;&gt;&amp;lrm;&lt;/span&gt;دست&lt;span dir=&quot;LTR&quot;&gt;&amp;lrm;&lt;/span&gt;آمده از این تحقیق نشان دادندکه کاربرد فرآیندهای ترکیبی انعقاد شیمیایی، ازن زنی و اکسیداسیون پیشرفته به&lt;span dir=&quot;LTR&quot;&gt;&amp;lrm;&lt;/span&gt;وسیله آکسون فعال&#8204;شده باپرتو فرابنفش،در حذف آلاینده&lt;span dir=&quot;LTR&quot;&gt;&amp;lrm;&lt;/span&gt;های مهم موجود در شیرابه محل دفن پسماند از کارایی بالایی برخوردار است.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background andpurpose:&lt;/strong&gt;Currently, leachate production and its management are major environmental problems associated with the operation of solid waste landfill. The aim of this study was to evaluate the efficiency of combined processes of coagulation, ozonation, and advanced oxidation using UV-activated oxone in treatment of landfill leachate of Zahedan, Iran.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Materials andmethods:&lt;/strong&gt; This experimental-laboratory study included chemical coagulation using poly aluminum chloride (PAC), ozonation, and chemical oxidation using potassium peroxymonosulfate (oxone). For the purpose of this study, the effect of critical operating parameters on treatment of landfill leachate was investigated. These operating parameteres included: pH (3-8) and concentration of PAC (50-250 mg/l) in chemical coagulation process,time of ozonation (5-20 min), pH of solution (2-10), concentration of oxone reactant (150-750 mg/l), contact time with oxone (60-360 min), temperature (20-45&amp;ordm;C), and intensity of UV lamp in oxidation process using oxone (8, 15, 30 W).&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; According to the results, the overall efficiency rates of this process in removal of total coliform, fecal coliform, total phosphorus, total nitrogen, biochemical oxygen demand (BOD), and chemical oxygen demand (COD)were 99%, 99%, 97%, 100%, 91.1%, and 85.62%, respectively, with optimum&lt;br clear=&quot;all&quot; &gt;
PAC concentration= 250 mg/L, pH= 6 at the chemical coagulation phase, ozonation duration= 20 min,&lt;br clear=&quot;all&quot; &gt;
reactiontime= 180 min during oxone-based oxidation process, oxone concentration= 750 mg/L, pH= 5, temperature= 25&amp;ordm;C, and UV lamp intensity= 8 W. Furthermore, the BOD&lt;sub&gt;5&lt;/sub&gt;/COD ratio increased from 0.42 to 0.72 after completion of the treatment process.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt;Current study showed that application of combined processes of chemical coagulation, ozonation, and advanced oxidation using UV-activated oxone are highlyefficient in removing major pollutants from waste landfill leachate.&lt;/p&gt;
</abstract>
	<keyword_fa> ازن زنی,آکسون, اکسیداسیون پیشرفته, انعقاد شیمیایی, شیرابه</keyword_fa>
	<keyword>advanced oxidation, chemical coagulation,leachate, oxone,ozonation

</keyword>
	<start_page>339</start_page>
	<end_page>357</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-4374-53&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Zahra </first_name>
	<middle_name></middle_name>
	<last_name>Maghsoudi</last_name>
	<suffix></suffix>
	<first_name_fa>زهرا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مقصودی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460083900</code>
	<orcid>100319475328460083900</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد مهندسی بهداشت محیط، دانشگاه علوم پزشکی زاهدان، زاهدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Edris </first_name>
	<middle_name></middle_name>
	<last_name>Bazrafshan</last_name>
	<suffix></suffix>
	<first_name_fa>ادریس</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بذرافشان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ed_bazrafshan@yahoo.com</email>
	<code>100319475328460083901</code>
	<orcid>100319475328460083901</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>استاد، مرکز تحقیقات ارتقای سلامت، دانشکده بهداشت، دانشگاه علوم پزشکی زاهدان، زاهدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Ferdous</first_name>
	<middle_name></middle_name>
	<last_name> Kord Mostafapour</last_name>
	<suffix></suffix>
	<first_name_fa>فردوس</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کرد مصطفی پور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460083902</code>
	<orcid>100319475328460083902</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشیار، گروه مهندسی بهداشت محیط، مرکز تحقیقات ارتقای سلامت دانشگاه علوم پزشکی زاهدان، زاهدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Parisa </first_name>
	<middle_name></middle_name>
	<last_name>Tavasoli</last_name>
	<suffix></suffix>
	<first_name_fa>پریسا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>توسلی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460083903</code>
	<orcid>100319475328460083903</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد مهندسی بهداشت محیط، دانشگاه علوم پزشکی زاهدان، زاهدان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Davoud </first_name>
	<middle_name></middle_name>
	<last_name>Balarak</last_name>
	<suffix></suffix>
	<first_name_fa>داوود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بلارک</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460083904</code>
	<orcid>100319475328460083904</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>مربی، گروه مهندسی بهداشت محیط، مرکز تحقیقات ارتقای سلامت دانشگاه علوم پزشکی زاهدان، زاهدان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
