<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Mazandaran University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی مازندران</title_fa>
<short_title>J Mazandaran Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jmums.mazums.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1735-9260</journal_id_issn>
<journal_id_issn_online>1735-9279</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2015</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>24</volume>
<number>120</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>برآورد ضرایب تصحیح برای پرتودرمانی میدان‌های کوچک با استفاده از انرژی‌های ۶ و ۱۸ مگاولتی یک شتاب‌دهنده خطی</title_fa>
	<title>Determination of Correction Factors for Small Field Radiotherapy Using 6 and 18MV Energies of a Linac</title>
	<subject_fa>فیزیک پزشکی</subject_fa>
	<subject>Medical physics</subject>
	<content_type_fa>پژوهشي-کامل</content_type_fa>
	<content_type>Research(Original)</content_type>
	<abstract_fa>&lt;div align=&quot;right&quot; style=&quot;direction: rtl&quot;&gt;
سابقه و هدف: برآورد صحیح پارامترهای دوزیمتری میدان‌های کوچک در شرایط غیرمرجع بر مبنای پروتکل‌های پرتودرمانی میدان‌های بزرگ و شرایط مرجع منجر به خطایی بیش از مقادیر توصیه شده می‌شود. هدف این تحقیق اندازه‌گیری و مقایسه ضرایب تصحیح (K&lt;sub&gt;NR&lt;/sub&gt; و K&lt;sub&gt;NCSF&lt;/sub&gt;) میدان‌های کوچک بر مبنای پروتکلهای جدید با آشکارسازها مختلف بوده است. 
مواد و روش‌ها: کولیماتورهای خاصی طراحی و ساخته و با نصب آنها بر روی یک شتابدهنده خطی پزشکی میدان‌های کوچک دایره‌ای با قطرهای ۵ و ۳۰ میلی‌متر برای پرتودرمانی ایجاد شد. سپس، ضرایب تصحیح K&lt;sub&gt;NR&lt;/sub&gt; و K&lt;sub&gt;NCSF&lt;/sub&gt;، بر مبنای پروتکل جدید (TG155) که برای دوزیمتری در میدان‌های کوچک معرفی شده، برای آشکارسازهای فعال مختلف (اتاقک یونیزاسیون، دیودهای EDP20 و EDP10) در یک فانتوم همگن و یک فانتوم ناهمگن در میدانهایی به ابعاد فوق و برای انرژی‌های ۶ و ۱۸ مگاولت یک شتابدهنده خطی واریان اندازه‌گیری شد.&lt;br&gt; یافته‌ها: ضریب تصحیح K&lt;sub&gt;NR&lt;/sub&gt; در میدان دایره‌ای به قطر 30 میلی‌متر برای اتاقک یونیزاسیون، دیودهای EDP20 و EDP10 در انرژی ۶ مگاولت به ترتیب 0.993 1.020 و 1.054 و در انرژی 18 مگاولت 0.992، 1.054 و 1.005 بود. ضریب تصحیح K&lt;sub&gt;NCSF&lt;/sub&gt; در میدان دایره‌ای به قطر ۵ میلی‌متر برای اتاقک یونیزاسیون، دیودهای EDP20 و EDP10 در انرژی ۶ مگاولت به ترتیب 0.994، 1.023 و 1.040 و در انرژی 18 مگاولت 1.000 ،1.014 و 1.022 بود.
استنتاج: نتایج نشان داد به کارگیری ضرایب تصحیح که بر اساس پروتکل جدید پیشنهادی برای دوزیمتری میدان‌های کوچک برآورد شدند، موجب افزایش دقت و صحت پرتودرمانی این میدان‌ها می‌شود. همچنین، در نظر گرفتن آشفتگی‌های ایجاد شده بین مرزهای ناحیه ناهمگن می‌تواند موجب افزایش دقت دوزیمتری در چنان شرایطی شود.

&lt;/div&gt;
</abstract_fa>
	<abstract>Abstract
Background and purpose: Estimating dosimetric parameters for small fields at non-reference
conditions lead to significant errors if they are done based on the conventional protocols used for large
fields and reference conditions. The aim of this study was to determine and compare small fields
correction factors (K&lt;sub&gt;NR&lt;/sub&gt; and K&lt;sub&gt;NCSF&lt;/sub&gt;) based on a novel protocol by using different types of detectors.
Materials and methods: Specific circular cones were constructed and attached to a medical linac
head to produce small field sizes down to 30 and 5mm diameters. Then, the K&lt;sub&gt;NR&lt;/sub&gt; and K&lt;sub&gt;NCSF&lt;/sub&gt; correction
factors based on a recent protocol (TG155), proposed for small field dosimetry formalism, were determined
for different active detectors (a pinpoint chamber, EDP20 and EDP10 diodes) in a homogeneous and a nonhomogeneous
phantom at the above fields when irradiated to 6 and 18 MV beams of a Varian linac.&lt;br&gt;Results: The K&lt;sub&gt;NR&lt;/sub&gt; correction factors for the circle field of 30mm estimated for the pinpoint
chamber, EDP20 and EDP10 diodes were 0.993, 1.020 and 1.054 at 6 MV and 0.992, 1.054 and 1.005 at
18 MV, respectively. The K&lt;sub&gt;NCSF&lt;/sub&gt; correction factor for the 5mm circle field estimated for the pinpoint
chamber, EDP20 and EDP10 diodes were 0.994, 1.023 and 1.040 at 6MV and 1.000, 1.014 and 1.022 at
18MV, respectively.
Conclusion: Our results indicated that implementing the correction factors estimated for the
small fields based on the new proposed dosimetry protocol increases the dosimetric precision and
accuracy of such fields in radiotherapy practices. Also, considering the perturbations happening between
the boundaries of non-homogeneous area could increase the accuracy of the dosimetry procedures in such
conditions.
</abstract>
	<keyword_fa>میدان کوچک, ضرایب تصحیح , دوزیمتر دیودی, TG155, فانتوم ناهمگن</keyword_fa>
	<keyword>Correction factors, Diode dosimeters, Non-homogeneous phantom, Small field, TG155</keyword>
	<start_page>173</start_page>
	<end_page>187</end_page>
	<web_url>http://jmums.mazums.ac.ir/browse.php?a_code=A-10-4374-14&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Ali </first_name>
	<middle_name></middle_name>
	<last_name>Rahimi</last_name>
	<suffix></suffix>
	<first_name_fa>علی </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رحیمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460043560</code>
	<orcid>100319475328460043560</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه تربیت مدرس، تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Bijan </first_name>
	<middle_name></middle_name>
	<last_name>Hashemi</last_name>
	<suffix></suffix>
	<first_name_fa>بیژن </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هاشمی </last_name_fa>
	<suffix_fa></suffix_fa>
	<email>bhashemi@modares.ac.ir</email>
	<code>100319475328460043561</code>
	<orcid>100319475328460043561</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه تربیت مدرس، تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Rabie </first_name>
	<middle_name></middle_name>
	<last_name>Mahdavi</last_name>
	<suffix></suffix>
	<first_name_fa>ربیع </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مهدوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460043562</code>
	<orcid>100319475328460043562</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Physics, Faculty of Medical Sciences, Iran University of Medical Sciences, Tehran</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی ایران، گروه فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه علوم پزشکی ایران، تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hadi </first_name>
	<middle_name></middle_name>
	<last_name>Molana</last_name>
	<suffix></suffix>
	<first_name_fa>هادی </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مولانا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>100319475328460043563</code>
	<orcid>100319475328460043563</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Radiotherapy, BESAT Hospital, Tehran</affiliation>
	<affiliation_fa>بخش رادیوتراپی، بیمارستان بعثت تهران، تهران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
