Volume 26, Issue 137 (6-2016)                   J Mazandaran Univ Med Sci 2016, 26(137): 196-205 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Alizadeh A, Sorayamahabed A, Soleymani S, Yazdani Charati J. Illuminance Intensity in Primary Schools in Sari, 2014. J Mazandaran Univ Med Sci 2016; 26 (137) :196-205
URL: http://jmums.mazums.ac.ir/article-1-7706-en.html
Abstract:   (6081 Views)

Materials and methods: In a descriptive cross-sectional study, 50 schools were selected by random sampling and the illuminance was measured using network method. In each place 2 to 10 measurements (between 8:00 AM and 14:00) were done using Lux meter (TES; A1336). Data was analyzed by GEE in SPSS V. 20.

Results: The lighting intensity was measured in 306 places including 194 classrooms, 49 offices and 63 corridors. Our evaluation showed that 34% of the classrooms, 40.8% of the offices, and 33% of the corridors had appropriate standard illuminance.

Conclusion: This research showed that incorrect layout of windows, the materials and colors of the walls and the material of the floors and curtain styles had significant effect on the lighting of the places.

Full-Text [PDF 464 kb]   (2439 Downloads)    
Type of Study: Research(Original) |

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Journal of Mazandaran University of Medical Sciences

Designed & Developed by : Yektaweb